Results 51 to 60 of about 422 (132)
This study explores the effects of anodic, cathodic, and open circuit (OCP) potentials on the tribocorrosion behaviour of the UNS S32205 duplex stainless steel, which is largely used in oil, gas, and cellulose industry.
Jomar José Knaip Ribeiro +4 more
doaj +1 more source
Effect of microstructure on tribocorrosion of FH36 low-temperature steels
The tribocorrosion performance of low-temperature steels is vital for use in hostile environments. This study aims to investigate the tribocorrosion behavior of FH36 low-temperature steel with two distinct microstructures of tempered martensite (TM) and ...
Shi Liang +5 more
doaj +1 more source
ABSTRACT This study introduces novel nonequiatomic TiZrCoCrMoCux (x = 0, 5, 10; at%) medium‐entropy alloys (MEAx) tailored for orthopedic implants, synergistically combining the biocompatibility of Ti‐based alloys, the wear resistance of CoCrMo alloys, and the antibacterial/osteogenic attributes of Cu. The alloy's microstructure, mechanical properties,
Hang Yu +9 more
wiley +1 more source
ABSTRACT Retrieved hip implant components experience a range of corrosion types and severity, often on small surface areas of the taper region. Tribocorrosion‐related damage within modular taper regions and resulting changes of the oxide‐covered surface can alter the local impedance of the interface.
Aarti A. Shenoy, Jeremy L. Gilbert
wiley +1 more source
In Vitro Evaluation of Hemiarthroplasty Bearing Materials: A Scoping Review (Part I)
ABSTRACT Hemiarthroplasty is used to treat joint damage confined to one side, aiming to preserve the remaining healthy cartilage and bone while addressing conditions like femur fractures and osteonecrosis; however, challenges persist due to cartilage wear and inconsistent clinical outcomes.
Victoria P. Marino +6 more
wiley +1 more source
Electrostatically Assembled HA–DN/AMSN–TCS Coatings for Antibacterial Urinary Catheters
ABSTRACT Catheter‐associated urinary tract infections (CAUTIs) are a significant complication of indwelling urinary catheters, primarily caused by bacterial adhesion, biofilm formation and catheter‐induced mechanical irritation. To reduce the risk of infection and enhance catheter safety and performance, this study developed an antibacterial ...
Jiafeng Hu +4 more
wiley +1 more source
Comparison of tribological and corrosion characteristics of AISI 316Ti and AISI 430 stainless steels
This study presents an investigation into the tribological, corrosion, and tribocorrosion properties of AISI 316Ti (austenitic) and AISI 430 (ferritic) stainless steels.
Čuchor Dávid +4 more
doaj +1 more source
Adverse local tissue reaction (ALTR) and pseudotumor formation, representing inflammatory responses to wear debris that lead to osteolytic lesions, remain major long‐term complications of total hip replacement. Hard‐bearing total hip prostheses with improved tribological properties—particularly large‐diameter head (LDH) ceramic‐on‐ceramic (CoC ...
M. Olivieri +10 more
wiley +1 more source
Tribocorrosion – Insight into Material Degradation in Specific Environments
Tribocorrosion is an irreversible surface degradation mechanism of a metallic and/or non-metallic material as a result of its physicochemical and mechanical interactions during relative motion (friction, sliding, impact, abrasion, erosion) in corrosive ...
Sorin-Bogdan BAŞA, Lidia BENEA
doaj
Introduction and Aim The aim of this study was to compare the influence of zirconia dioxide nanoparticles (ZrO2‐NPs) and titanium dioxide nanoparticles (TiO2‐NPs) on the functionality of osteocytes in vitro. Methods MLO‐Y4 osteocytic cells were treated with varying concentrations of ZrO2‐NPs or TiO2‐NPs for viability studies. Apoptosis assays following
Mustafa Hayder Matouk +6 more
wiley +1 more source

