Results 61 to 70 of about 65,752 (169)
Safety and efficacy of direct 1.1‐mm cryobiopsy specimen retrieval through a 3.0‐mm therapeutic bronchoscope channel were evaluated. The technique achieved 87.5% overall diagnostic yield, produced specimens three times larger than forceps biopsy, and caused Grade 3 bleeding in only 2.1%.
Yuki Takigawa +13 more
wiley +1 more source
This case series reports the initial clinical experience using a novel, single‐use transbronchial puncture dilatation catheter compatible with thin bronchoscopes. In two distinct cases involving a lung nodule with negative bronchus sign and a stenotic airway, the device successfully facilitated ‘off‐road’ access and radial EBUS verification, enabling ...
Sze Shyang Kho, Chan Sin Chai
wiley +1 more source
Bronchoscopy in Rural Areas? [PDF]
Quality of bronchoscopy performed by one single pulmonologist in a scarcely populated subarctic area was compared to the guidelines provided by the British Thoracic Society (BTS). 103 patients underwent bronchoscopy. Diagnostic yield was increased to 76.
Erik Waage Nielsen, Reidar Berntsen
core +1 more source
Breathomics is established as a non‐invasive diagnostic strategy by combining volatile organic compound biomarkers, nanomaterial‐based sensor arrays, and AI‐driven classification. Key diseases, sensing materials, and analytical challenges are critically compared, revealing how portable, data‐enabled breath platforms are moving toward clinically useful ...
Anesu Nyabadza +3 more
wiley +1 more source
Radial EBUS‐guided transbronchial cryobiopsy using a 1.1‐mm cryoprobe achieved a 75.3% diagnostic yield for peripheral lung lesions in 73 patients, with no severe hemorrhage. Protocolized balloon blocker use effectively controlled all bleeding events, supporting cryobiopsy as a feasible, safe alternative to conventional forceps biopsy.
Lamya Chrif Morand +4 more
wiley +1 more source
Electrical and chemical characterisation of ultrathin transistor gate dielectric layers [PDF]
This work examines the suitability of both ultrathin Silicon Oxynitride (SiON) and Hafnium Silicate (HfSiON) layers to be used as high-permittivity gate dielectrics to serve as a replacement to silicon dioxide (Si0 2 )in future Metal-Oxide-Semiconductor (
O'Connor, Robert, O\u27Connor, Robert
core +2 more sources
The indication of bronchoscopy.
The indication of bronchoscopy.
Jong Geol Jang (13007079) +5 more
core +1 more source
Background A 3.0-mm ultrathin bronchoscope (UTB) with a 1.7-mm working channel provides better accessibility to peripheral bronchi. A 4.0-mm thin bronchoscope with a larger 2.0-mm working channel facilitates the use of a guide sheath (GS), ensuring ...
Xinying Sun +12 more
doaj +1 more source
A cascade‐responsive MXene@Cu‐MOF/GelMA hydrogel is engineered as a “skeleton–backpack” platform for extensive tracheal repair. The MXene framework scavenges postoperative ROS and converts NIR light into mild hyperthermia, while the Cu‐MOF component provides pH/NIR‐responsive Cu2+ dosing for infection control, angiogenesis, and chondrogenesis.
Liang Guo +8 more
wiley +1 more source
Application of Interventional Bronchoscopy in Pulmonary Peripheral Lesions
Lung cancer is the leading cause of cancer-related mortality worldwide. A low cure rate of lung cancer is not only attributed to intrinsic aggressive biological behavior, but also little attention to lung cancer screening.
Hui WANG, Linian HUANG
doaj +1 more source