DC vacuum circuit-breaker

2008 23rd International Symposium on Discharges and Electrical Insulation in Vacuum, 2008
The results of switching tests of a DC vacuum circuit-breaker designed for rated voltage 3.3 kV and rated current 3000A are presented. The circuit-breaker is intended for current interruption in the networks with fault currents up to 30 kA. To interrupt the direct current, the authors used a method of artificial current transition through zero in the ...
D. Alferov   +5 more
openaire   +1 more source

HYDC Vacuum Circuit Breakers

IEEE Transactions on Power Apparatus and Systems, 1972
The effectiveness of the commutation principle, using vacuum interrupters as a means for interrupting high direct current at high voltage, has been demonstrated convincingly by a large number of tests. Currents in excess of 15 kA at 20 kV have been interrupted by a single device in an inductive circuit.
A. Greenwood, P. Barkan, W. Kracht
openaire   +1 more source

Vacuum-state estimation of vacuum circuit breakers

SPIE Proceedings, 1994
The vacuum state of vacuum switching elements after production is checked normally by Penning- or Magnetron methods (combined electrical and magnetic field). Vacuum in the range of 10-1 - 10-4 Pa can be measured in this way. After assembly into circuit breakers however, these methods are not applicable.
Damstra, G.C.   +2 more
openaire   +2 more sources

High voltage vacuum circuit breakers

IEEE Transactions on Power Apparatus and Systems, 1975
A new line of high voltage vacuum power circuit breakers is being developed for 121 kV and above and will use the new vacuum interrupter module presented in a companion paper3. The first ratings in production will be 242 kV with interrupting capabilities of 40,000 amperes, followed by breakers rated 50,000 amperes; both of these will have continuous ...
R.B. Shores, V.E. Phillips
openaire   +1 more source

Low Surge Vacuum Circuit Breakers

IEEE Power Engineering Review, 1985
Low surge vacuum circuit breakers were developed which used a new electrode material cobalt-silver-selenium alloy. Their chopping current level was below 1.0 A and their high frequency current interruption ability was about 24 Aus. These levels were much lower than those of conventional electrode materials and did not change after load current ...
Y. Kurosawa   +5 more
openaire   +1 more source

Estimation of vacuum condition in vacuum circuit breakers

Proceedings ISDEIV. 18th International Symposium on Discharges and Electrical Insulation in Vacuum (Cat. No.98CH36073), 2002
In this paper a method is described for the estimation of the pressure inside vacuum circuit breakers which have been in operation for several years. The method is applicable for measurements in the field and uses only electrical measurement techniques.
Merck, W.F.H.   +2 more
openaire   +2 more sources