Chromatographic analysis and monitoring of fault gases in substation using ZIF-8 coated capillary column. [PDF]
Mao H +10 more
europepmc +1 more source
A new airtight sampling method for sulfur hexafluoride (SF6) in groundwater. [PDF]
Sunderland R +3 more
europepmc +1 more source
Overview of Monitoring, Diagnostics, Aging Analysis, and Maintenance Strategies in High-Voltage AC/DC XLPE Cable Systems. [PDF]
Emdadi K +4 more
europepmc +1 more source
High-entropy solvation chemistry towards affordable and practical Ah-level zinc metal battery. [PDF]
Chang L +9 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
A Guide to the Application of Vacuum Circuit Breakers
IEEE Transactions on Power Apparatus and Systems / Technical Operations Committee, 1971The paper shows that the vacuum circuit breaker is well suited for the duties that a circuit breaker must perform. Reasonable care must be taken under certain circumstances when applying these breakers. Such applications are identified and simple corrective measures are proposed.
A Greenwood
exaly +2 more sources
1982
The vacuum circuit breaker has fascinated the switchgear designer for many years, primarily because of the great advantages of vacuum interrupters, which are: (a) They are entirely self contained, need no supplies of gases or liquids and emit no flame or gas.
openaire +1 more source
The vacuum circuit breaker has fascinated the switchgear designer for many years, primarily because of the great advantages of vacuum interrupters, which are: (a) They are entirely self contained, need no supplies of gases or liquids and emit no flame or gas.
openaire +1 more source
The testing of vacuum generator circuit breakers
IET Conference Publications, 2009Testing of generator breakers is usually in accordance with the standard IEEE Std. C37.013, to be included in the IEC framework soon.
Smeets, R.P.P. +4 more
openaire +2 more sources
Vacuum circuit breaker with asymmetrical actuator
IEEE/PES Transmission and Distribution Conference and Exhibition, 2003During the last decades vacuum replaced air, oil and almost SF/sub 6/ as switching medium in medium voltage circuit breakers. Beside the ecological and economic advantages vacuum is a proper solution for all switching applications. The range of applications last from switching of loads, such as transformers, motors to the switching of short circuit ...
openaire +1 more source
Low Surge Vacuum Circuit Breakers
IEEE Power Engineering Review, 1985Low surge vacuum circuit breakers were developed which used a new electrode material cobalt-silver-selenium alloy. Their chopping current level was below 1.0 A and their high frequency current interruption ability was about 24 Aus. These levels were much lower than those of conventional electrode materials and did not change after load current ...
Y. Kurosawa +5 more
openaire +1 more source