Results 11 to 20 of about 8,814 (230)
Directions of Development of Diagnostic Methods of Vacuum Medium-Voltage Switchgear
The development of power grid infrastructure and increasingly stringent environmental regulations have intensified work, carried out by researchers and electrical equipment manufacturers, to develop innovative gas-insulated, environmentally neutral ...
Paweł Węgierek +2 more
doaj +1 more source
Transformers and circuit breakers are essential equipment in traction power supply systems. Once a fault occurs, it will affect the train’s regular operation and even threaten passengers’ personal safety. Therefore, it is essential to diagnose the faults
Zhensheng Wu +4 more
doaj +1 more source
On fully superconducting rectifiers and fluxpumps. A review. Part 2: Commutation modes, characteristics and switches [PDF]
This paper forms the second part of the review. Full and half wave superconducting transformer rectifiers are analysed. Modes of operation and loss mechanisms are detailed and a comparison between the behaviour of dynamos and rectifiers is presented ...
Kate, H.H.J. ten +1 more
core +2 more sources
In the last years the progressive increase of distributed and non-programmable energy sources arise the interest in the use of DC for medium-voltage distribution systems. The study focuses on the design considerations of the apparatus required to support the management and protection of these applications.
Lars Liljestrand +4 more
openaire +1 more source
Voltage transient management for Alternating Current trains with vacuum circuit breakers
Alternating current power supplies and rolling stock with 25 kV (50 or 60 Hz) and 15 kV (16.7 Hz) traction systems do not have the characteristics and behaviour of a typical three‐phase medium‐voltage distribution system. Switching inductive loads with a
Thomas Moore +2 more
doaj +1 more source
Optimisation of commutation circuit parameters for DC vacuum circuit breakers
As the environmental problems caused by the consumption of the non-renewable fossil energy are getting increasingly serious, the new energy power generation has received wide attentions.
Deen Yu, Hai Chen, Wei Liu, Xiaoming Liu
doaj +1 more source
Vacuum circuit breaker current-zero phenomena [PDF]
Post-arc current phenomena that occur when interrupting high currents with vacuum circuit breakers have been investigated. High resolution measuring equipment has been used to measure both the post-arc current and the arc voltage in the current-zero region. Three examples of frequently observed phenomena are described.
van Lanen, E.P.A. (author) +3 more
openaire +2 more sources
System configuration, fault detection, location, isolation and restoration: a review on LVDC Microgrid protections [PDF]
Low voltage direct current (LVDC) distribution has gained the significant interest of research due to the advancements in power conversion technologies. However, the use of converters has given rise to several technical issues regarding their protections
Bououden +11 more
core +1 more source
The objective of this paper is to determine the transient characteristics and sites of the pre‐breakdown (pre‐BD) in the spark conditioning under power frequency voltage (PFV) in vacuum.
Hui Ma +7 more
doaj +1 more source
Simulation study on modeling of vacuum arc characteristics and anode temperature rise in low-frequency vacuum interruption [PDF]
Low-frequency transmission technology has been widely used in medium- and long-distance electricity transmission scenarios such as offshore wind power transmission due to its advantages of low cost and strong ability to pool renewable energy.
Yanting Li +6 more
doaj +1 more source