Results 41 to 50 of about 1,189,988 (126)

Graphene-Enhanced CuW Composites for High-Voltage Circuit Breaker Electrical Contacts

open access: yesApplied Sciences
To address the issue of over-standard short-circuit currents in a power system, it is imperative to enhance the comprehensive performance of the electrical contacts, which serve as the lynchpin of circuit breakers, so as to improve the breaking capacity ...
Tan Liu   +6 more
doaj   +1 more source

The Impact of Various Contact Structures on the Microscopic Surface Condition of Vacuum Interrupters During Capacitive Switching

open access: yesHigh Voltage, EarlyView.
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng   +6 more
wiley   +1 more source

The Role OF Vacuum Circuit Breakers in Traction Substations

open access: yes, 2020
This paper investigates major points of the role of vacuum circuit breakers in traction substations. Therefore, research has been analyzed both analytical and theoretical aspects of the circuit breakers in traction cases. In conclusion, research has been
Rustemovna, R. A. (Rustemova)   +1 more
core  

Transient characteristics and sites of pre‐breakdown in spark conditioning for high‐voltage vacuum interrupter under power frequency voltage

open access: yesIET Generation, Transmission & Distribution, 2023
The objective of this paper is to determine the transient characteristics and sites of the pre‐breakdown (pre‐BD) in the spark conditioning under power frequency voltage (PFV) in vacuum.
Hui Ma   +7 more
doaj   +1 more source

Insulation–Vibration Dynamics Model and Experimental Investigation of Cable Gas‐Insulated Switchgear Terminations

open access: yesHigh Voltage, EarlyView.
ABSTRACT Numerous breakdowns in cable gas‐insulated switchgear (GIS) terminations stem from inadequate insulation and interfacial stresses. However, existing diagnostic techniques, such as partial discharge detection and microwave detection, are highly susceptible to electromagnetic interference, or their diagnostic signals are often attenuated by the ...
Zeyan Zhang, Binlong Cao, Zhidong Jia
wiley   +1 more source

REPLACMENT OF AIR CIRCUIT BREAKERS WITH VACUUM CIRCUIT BREAKERS ON 6,3 kV LEVEL IN KRŠKO NUCLEAR POWER PLANT [PDF]

open access: yes, 2010
Cilj diplomske naloge je predstaviti problem in predlagati rešitev za obstoječe zračne odklopnike na srednjenapetostnem 6,3 kV nivoju v NEK, ki se jim izteka življenjska doba.
Ošlovnik, Matjaž
core  

Research of Health Diagnosis Strategy with Neural Network of Vacuum Circuit Breakers of 10 kV Switchgear

open access: yesGong-kuang zidonghua, 2011
In order to solve problems of lack maintenance and blind repair existed in vacuum circuit breakers of 10 kV switchgear , the paper put forward a health diagnosis strategy of vacuum circuit breaker of 10 kV switchgear based on RBF neural network on basis ...
HE Lan, LIU Xing, WANG Dan-dan
doaj  

Counter‐Plantation Imaginaries: Deproletarianisation and Struggle for Autonomy in India

open access: yesJournal of Agrarian Change, EarlyView.
ABSTRACT This article examines the decline of the 2015 Pembillai Orumai movement in India's Munnar tea belt as an event revealing the dialectical relationship between labour struggle and agrarian capitalism within the plantation complex. Although widely celebrated for securing wage gains through a historic Dalit woman–led strike, the movement's rapid ...
Jayaseelan Raj
wiley   +1 more source

Arc root commutation from moving contacts in low voltage devices [PDF]

open access: yes, 2000
This paper focus on the arc commutation from a moving contact and in particular on the anode motion of a high current arc in low voltage current limiting circuit breakers.
Weaver, P.M.   +6 more
core   +1 more source

Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor

open access: yesEnergies
When a 35 kV distribution network has the problem of insufficient reactive power, the input of a shunt reactor is a common compensation method. Vacuum circuit breakers are widely used in 35 kV distribution networks because of their superior arc ...
Jing Chen   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy