Graphene-Enhanced CuW Composites for High-Voltage Circuit Breaker Electrical Contacts
To address the issue of over-standard short-circuit currents in a power system, it is imperative to enhance the comprehensive performance of the electrical contacts, which serve as the lynchpin of circuit breakers, so as to improve the breaking capacity ...
Tan Liu +6 more
doaj +1 more source
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng +6 more
wiley +1 more source
The Role OF Vacuum Circuit Breakers in Traction Substations
This paper investigates major points of the role of vacuum circuit breakers in traction substations. Therefore, research has been analyzed both analytical and theoretical aspects of the circuit breakers in traction cases. In conclusion, research has been
Rustemovna, R. A. (Rustemova) +1 more
core
The objective of this paper is to determine the transient characteristics and sites of the pre‐breakdown (pre‐BD) in the spark conditioning under power frequency voltage (PFV) in vacuum.
Hui Ma +7 more
doaj +1 more source
ABSTRACT Numerous breakdowns in cable gas‐insulated switchgear (GIS) terminations stem from inadequate insulation and interfacial stresses. However, existing diagnostic techniques, such as partial discharge detection and microwave detection, are highly susceptible to electromagnetic interference, or their diagnostic signals are often attenuated by the ...
Zeyan Zhang, Binlong Cao, Zhidong Jia
wiley +1 more source
REPLACMENT OF AIR CIRCUIT BREAKERS WITH VACUUM CIRCUIT BREAKERS ON 6,3 kV LEVEL IN KRŠKO NUCLEAR POWER PLANT [PDF]
Cilj diplomske naloge je predstaviti problem in predlagati rešitev za obstoječe zračne odklopnike na srednjenapetostnem 6,3 kV nivoju v NEK, ki se jim izteka življenjska doba.
Ošlovnik, Matjaž
core
In order to solve problems of lack maintenance and blind repair existed in vacuum circuit breakers of 10 kV switchgear , the paper put forward a health diagnosis strategy of vacuum circuit breaker of 10 kV switchgear based on RBF neural network on basis ...
HE Lan, LIU Xing, WANG Dan-dan
doaj
Counter‐Plantation Imaginaries: Deproletarianisation and Struggle for Autonomy in India
ABSTRACT This article examines the decline of the 2015 Pembillai Orumai movement in India's Munnar tea belt as an event revealing the dialectical relationship between labour struggle and agrarian capitalism within the plantation complex. Although widely celebrated for securing wage gains through a historic Dalit woman–led strike, the movement's rapid ...
Jayaseelan Raj
wiley +1 more source
Arc root commutation from moving contacts in low voltage devices [PDF]
This paper focus on the arc commutation from a moving contact and in particular on the anode motion of a high current arc in low voltage current limiting circuit breakers.
Weaver, P.M. +6 more
core +1 more source
Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor
When a 35 kV distribution network has the problem of insufficient reactive power, the input of a shunt reactor is a common compensation method. Vacuum circuit breakers are widely used in 35 kV distribution networks because of their superior arc ...
Jing Chen +4 more