Results 41 to 50 of about 818 (219)

Effect of Potential Distribution of Main Shield on Internal Insulation Performance of Vacuum Interrupter

open access: yesShanghai Jiaotong Daxue xuebao
As an environmentally friendly switchgear technology, vacuum circuit breakers have a wide range of application prospects. However, both single and break vacuum circuit breakers face the issues of uneven potential distribution in the main shielding case ...
CHENG Xian, LI Guanjun, GE Guowei, DU Shuai, ZHANG Wanlong
doaj   +1 more source

Surface Micro‐Discharge Plasma for Multiple Teeth Bleaching: Efficacy, Mechanism and Safety

open access: yesHigh Voltage, EarlyView.
ABSTRACT Hydrogen peroxide (H2O2) is the commonly‐used bleaching chemical in clinical practice, but its excessive concentrations can cause tooth damage. Atmospheric pressure cold plasma is considered a promising new technique for tooth bleaching. Surface micro‐discharge (SMD) devices can generate large‐scale plasma, which holds potential for treating ...
Ruike Chen   +7 more
wiley   +1 more source

Desenvolvimento de um sistema computacional para projetos de um atuador magnético biestável monobobina [PDF]

open access: yes, 2007
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica.RESUMO: O presente trabalho aborda o desenvolvimento e a análise de um sistema computacional para o auxílio em projetos ...
Aguillar, André Küll
core  

Post‐Arc Transient Dielectric Recovery Characteristics of Vacuum Interrupter in the Large‐Capacity Generator Circuit Breaker

open access: yesHigh Voltage, EarlyView.
ABSTRACT Large‐capacity generator circuit breaker (GCB) based on vacuum interrupter technology is the key power equipment to ensure the safe operation of the power system. When the short‐circuit current was forced to cross zero, the large‐capacity GCB was difficult to generate a zero‐voltage environment through freewheeling, the vacuum interrupter (VI)
Xiangyu Han   +8 more
wiley   +1 more source

Phenomenological approach to simulation of propagation of spots over cathodes of high-power vacuum circuit breakers [PDF]

open access: yes, 2016
A phenomenological description of an ensemble of a large number of spots on negative contacts of high-power vacuum circuit breakers is developed by means of generalization of the concept of random walk of a single cathode spot in low-current ...
W. Hartmann   +7 more
core   +1 more source

Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives

open access: yesHigh Voltage, EarlyView.
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu   +4 more
wiley   +1 more source

Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor

open access: yesEnergies
When a 35 kV distribution network has the problem of insufficient reactive power, the input of a shunt reactor is a common compensation method. Vacuum circuit breakers are widely used in 35 kV distribution networks because of their superior arc ...
Jing Chen   +4 more
doaj   +1 more source

Experimental investigations on the post-arc current of the vacuum circuit breaker in an active mechanical DC circuit breaker

open access: yesAIP Advances, 2021
Vacuum circuit breakers (VCB) are commonly used in active mechanical direct current circuit breakers (DC CBs) to accomplish the interruption of the fault current.
Shenli Jia   +3 more
doaj   +1 more source

The Impact of Various Contact Structures on the Microscopic Surface Condition of Vacuum Interrupters During Capacitive Switching

open access: yesHigh Voltage, EarlyView.
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng   +6 more
wiley   +1 more source

Analysis of transient overvoltages caused by vacuum circuit breakers switchings.

open access: yes, 2018
Esta dissertação realiza uma análise comparativa de sobretensões transitórias que ocorrem durante o chaveamento de disjuntores a vácuo. Estas sobretensões podem ocasionar a falha da isolação dos equipamentos conectados aos disjuntores, conforme vários ...
Bongiolo, Guilherme Grazziotin
core   +1 more source

Home - About - Disclaimer - Privacy