Online Monitoring Method for Opening and Closing Time of 10 kV Spring Energy Storage Circuit Breaker Based on Transient Electrical Signal Characteristic Point Marking and Self-Calibration

open access: yesEnergies
Among all circuit breaker faults, mechanical failures account for a considerable proportion, and online monitoring of their mechanical characteristics is of great practical significance.
Liting Weng   +8 more
doaj   +1 more source

The Influence of Mechanical Deformation Consideration on the Results of the Calculation of the Vacuum Circuit Breaker Drive Shaft

open access: yesJournal of Mechanical Engineering, 2023
One of the important directions of theoretical, computational and experimental research related to the improvement and development of new design elements of modern electrical devices, primarily medium voltage circuit breakers and contactors, is the study
Yevhen I. Baida   +2 more
doaj   +1 more source

The suitability of N2 to replace SF6 in a triggered spark-gap switch for pulsed power applications [PDF]

open access: yes, 2009
The high dielectric strength of sulphur hexafluoride (SF6) when compared with other gases, coupled with safety benefits such as non-flammability and non-toxicity, has seen the widespread use of SF6 for the insulation of switching components. However, SF6
Given, M.J.   +6 more
core  

Fossil Hegemony and Capitalist Realism in Tropic of Orange

open access: yesFuture Humanities, Volume 4, Issue 1, May 2026.
ABSTRACT This article examines Karen Tei Yamashita's Tropic of Orange (1997) through the lens of Mark Fisher's influential concept ‘capitalist realism’. Scholars of petrofiction have pointed to a political ambivalence in the representation of fossil fuels, where a better understanding of fossil capital can overwhelm as much as galvanize.
Claire Ravenscroft
wiley   +1 more source

Research of Health Diagnosis Strategy with Neural Network of Vacuum Circuit Breakers of 10 kV Switchgear

open access: yesGong-kuang zidonghua, 2011
In order to solve problems of lack maintenance and blind repair existed in vacuum circuit breakers of 10 kV switchgear , the paper put forward a health diagnosis strategy of vacuum circuit breaker of 10 kV switchgear based on RBF neural network on basis ...
HE Lan, LIU Xing, WANG Dan-dan
doaj  

Analysis of Arc Re-Ignition in Vacuum Interrupter-Based HVdc Circuit Breakers

open access: yesIEEE Access
The protection of HVdc systems has long been challenged by the absence of natural current zero-crossing, typically addressed using L-C branches. However, the phenomenon of multiple arc reignitions in vacuum interrupter (VI) based HVdc circuit breakers ...
Tamer Eliyan   +3 more
doaj   +1 more source

Pressure estimation in vacuum circuit breakers

open access: yesIEEE Transactions on Dielectrics and Electrical Insulation, 1995
The pressure of vacuum switching elements after production is checked normally by Penning or magnetron methods (combined electrical and magnetic field). Vacuum in the range of 10-1 to 10-4 Pa can be measured in this way. After assembly into circuit breakers however, these methods are not applicable. HF interruption performance during the make operation
Damstra, G.C.   +2 more
openaire   +1 more source

Ion Crowding Effect in Unilaterally Downsized Perovskite Memristors

open access: yesAdvanced Science, Volume 13, Issue 21, 13 April 2026.
The downscaling of perovskite memristors incorporating monocrystalline nanoplates is accompanied by an ion crowding effect, which greatly enhances the local electric field in the vicinity of electrode. The highly controlled crowding of anions and vacancies results in anisotropic switching characteristics as well as unique morphology modification ...
Conghui Tan   +11 more
wiley   +1 more source

A fuse‐based DC circuit breaker with vacuum interrupter enhanced by an external transverse magnetic field

open access: yesHigh Voltage
Due to the increasing power system capacity, the interruption of large fault currents has gradually become a major challenge in power systems. At the moment, such currents are interrupted mainly via circuit breakers based on the method of active current ...
Yu Xiao   +5 more
doaj   +1 more source

Condition Monitoring and Fault Diagnosis Model of Pole Mounted Circuit Breaker Based on Multi‐Source Heterogeneous Cross Modal Information Fusion

open access: yesEngineering Reports, Volume 8, Issue 4, April 2026.
This figure illustrates the architecture of the PMCB fault diagnosis model with multi‐source heterogeneous cross‐modal fusion. It integrates core modules to realize high‐precision, low false‐alarm condition monitoring and diagnosis. ABSTRACT Aiming at the defects of current diagnosis methods for Primary and Secondary Integrated Pole Mounted Circuit ...
Rongrong Shan   +3 more
wiley   +1 more source