Results 11 to 20 of about 1,555 (283)
Effect of Cr@RGO structure on microstructure and properties of RGO/CuCr25 composite
CuCr alloy with high Cr content (20–50 wt.%) is the main contact material for medium voltage and high current vacuum interrupters. However, the influence of network distribution of Cr particles affect the conductivity of CuCr alloy, and its properties ...
Jinfeng Leng +5 more
doaj +1 more source
Breakdown performance of vacuum circuit breakers using alternative CF3I-CO2 insulation gas mixture [PDF]
In this paper, sulphur hexafluoride (SF6) insulated vacuum interrupter circuit breakers have been used to explore replacing SF6 gas with a trifluoroiodomethane and carbon dioxide (CF3I-CO2) gas mixture.
Griffiths, H., Haddad, A., Widger, P.
core +1 more source
Previous studies mainly focused on the behaviours of single‐break vacuum circuit breakers (VCBs) in switching capacitor banks. The prestrike characteristics of double‐break VCBs subjected to axial magnetic fields (AMFs) and transverse magnetic fields ...
Yun Geng +6 more
doaj +1 more source
CuCr alloys are the main contact materials used in medium-voltage and high-current vacuum interrupters. In this paper, the effect of large plastic deformation on microstructure and the transverse/longitudinal thermal conductivity of CuCr30 contact ...
Xiuhua Guo +5 more
doaj +1 more source
Direct comparison of high voltage breakdown measurements in liquid argon and liquid xenon [PDF]
As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design.
Bernard, EP +8 more
core +2 more sources
CuCr30 composite was commonly applied in medium and low voltage vacuum interrupters. The WC/CuCr30 composites based on changing of Cr particle morphology and orientation were successfully prepared by vacuum hot press sintering and hot extrusion, and the ...
Kaiyue Duan +7 more
doaj +1 more source
The dielectric recovery process has decisive effects on the current interruption process in vacuum circuit breakers, which has attracted the special attention of researchers.
Yongpeng Mo, Zongqian Shi, Shenli Jia
doaj +1 more source
Spark plasma sintering (SPS) is widely used for the consolidation of different materials. Copper-based pseudo alloys have found a variety of applications including as electrodes in vacuum interrupters of high-voltage electric circuits.
Kirill V. Kuskov +4 more
doaj +1 more source
In this paper, we present our research into the interruption performance of vacuum circuit breakers in aviation intermediate-frequency (360 Hz to 800 Hz) power supply systems. Intermediate-frequency vacuum arc experiments were carried out in interrupters
Yuan Jiang +3 more
doaj +1 more source
The prestrike phenomenon in vacuum circuit breakers (VCBs) is interesting but complicated. Previous studies mainly focus on the prestrike phenomenon in single-break VCBs. However, experimental work on prestrike characteristics of double-break VCBs cannot
Yun Geng +7 more
doaj +1 more source