Results 11 to 20 of about 450,905 (282)
Early counterpulse technique applied to vacuum interrupters [PDF]
Interruption of dc currents using counterpulse techniques is investigated with vacuum interrupters and a novel approach in which the counterpulse is applied before contact separation.
Warren, R.W., R.W. Warren
core +3 more sources
Publisher Copyright: © 2023 IEEJ.Vacuum interrupters are increasingly being used for applications outside the field of traditional medium voltage circuit breakers. One of these applications is low voltage distribution systems. Vacuum interrupters used in
Lopez, Severo Aranaga +5 more
core +1 more source
The experience gained in the study of conditioning of high voltage vacuum-isolated DC systems with X-ray detectors, which allows analysis of time windows with a resolution of a few tens of ns, suggested to explore the use of this technique for studying ...
Pilan N. +7 more
core +1 more source
Optical Diagnostics of Anode Surface Temperature in Vacuum Interrupters with Different CuCr Compositions [PDF]
The requirements for contact material in vacuum interrupters are demanding because the arc medium is formed by electrode evaporation during the operation. Copper chromium alloy (CuCr) is widely used as contact material.
Gortschakow, Sergey +5 more
core +1 more source
CuCr30 composite was commonly applied in medium and low voltage vacuum interrupters. The WC/CuCr30 composites based on changing of Cr particle morphology and orientation were successfully prepared by vacuum hot press sintering and hot extrusion, and the ...
Kaiyue Duan +7 more
doaj +1 more source
Experiments with vacuum interrupters used for large dc-current interruption [PDF]
Vacuum interrupters have been tested in circuits similar to those used in theta-pinch and Tokamak fusion devices. The effects on performance of auxiliary circuit components and axial magnetic fields have been determined, and limits to lifetime caused by ...
Warren, R.W.
core +1 more source
The prestrike phenomenon in vacuum circuit breakers (VCBs) is interesting but complicated. Previous studies mainly focus on the prestrike phenomenon in single-break VCBs. However, experimental work on prestrike characteristics of double-break VCBs cannot
Yun Geng +7 more
doaj +1 more source
The dielectric recovery process has decisive effects on the current interruption process in vacuum circuit breakers, which has attracted the special attention of researchers.
Yongpeng Mo, Zongqian Shi, Shenli Jia
doaj +1 more source
Spark plasma sintering (SPS) is widely used for the consolidation of different materials. Copper-based pseudo alloys have found a variety of applications including as electrodes in vacuum interrupters of high-voltage electric circuits.
Kirill V. Kuskov +4 more
doaj +1 more source
In this paper, we present our research into the interruption performance of vacuum circuit breakers in aviation intermediate-frequency (360 Hz to 800 Hz) power supply systems. Intermediate-frequency vacuum arc experiments were carried out in interrupters
Yuan Jiang +3 more
doaj +1 more source

