Results 121 to 130 of about 2,969 (154)
Mechanical ventilation in ARDS: navigating the fine line with real-time monitoring. [PDF]
Ball L +7 more
europepmc +1 more source
Ventilator Settings and Monitoring Variables Associated with Extubation Failure in Critically Ill Patients: A Retrospective Cohort Study. [PDF]
Steinberg E +9 more
europepmc +1 more source
Respiratory muscle dysfunction in mechanical ventilation: a systematic review and meta-analysis of biological mechanisms. [PDF]
González-Seguel F +10 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Ventilator-Induced Diaphragm Dysfunction
2021It was Vassilakopoulos and Petrof who first proposed the concept of ventilator-induced diaphragm dysfunction (VIDD) in 2004, which refers to the loss of diaphragmatic force-generating capacity that is specifically related to the use of mechanical ventilation [1].
Li Hong-Liang
exaly +2 more sources
Ruxolitinib Prevents Ventilator Induced Diaphragm Dysfunction
The FASEB Journal, 2022Mechanical ventilation (MV), however brief results in the loss of diaphragm muscle mass and strength, termed ventilator induced diaphragm dysfunction (VIDD). VIDD increases dependence, complicates and prolongs weaning and significantly increases discharge mortality rate and health care costs worldwide.
Alex B. Addinsall +8 more
openaire +1 more source
Rapid review of ventilator-induced diaphragm dysfunction
Respiratory MedicineVentilator-induced diaphragm dysfunction is gaining increased recognition. Evidence of diaphragm weakness can manifest within 12 h to a few days after the initiation of mechanical ventilation. Various noninvasive and invasive methods have been developed to assess diaphragm function.
Huimin Wu
exaly +3 more sources
The Signaling Network Resulting in Ventilator-induced Diaphragm Dysfunction
American Journal of Respiratory Cell and Molecular Biology, 2018Abstract Mechanical ventilation (MV) is a life-saving measure for those incapable of adequately ventilating or oxygenating without assistance. Unfortunately, even brief periods of MV result in diaphragm weakness (i.e., ventilator-induced diaphragm dysfunction [VIDD]) that may render it difficult to wean the ventilator. Prolonged MV is
Huibin, Tang, Joseph B, Shrager
exaly +3 more sources
Ruxolitinib: A new hope for ventilator‐induced diaphragm dysfunction
AbstractAimMechanical ventilation (MV) results in diminished diaphragm size and strength, termed ventilator‐induced diaphragm dysfunction (VIDD). VID increases dependence, prolongs weaning, and increases discharge mortality rates. The Janus kinase (JAK)/Signal Transducer and Activator of Transcription (STAT) pathway is implicated in VIDD, upregulated ...
Addinsall AB +10 more
exaly +5 more sources

