Results 61 to 70 of about 841,302 (182)
When two HVDC transmission lines run across, because of the interaction between the two lines, the maximum ground-level total electric field is not a simple superposition of the maximum ground-level total electric field generated when the two lines exist
Fengnyu Xiao +3 more
doaj +1 more source
Sensitive imaging of electromagnetic fields with paramagnetic polar molecules
We propose a method for sensitive parallel detection of low-frequency electromagnetic fields based on the fine structure interactions in paramagnetic polar molecules.
D. L. Andrews +5 more
core +1 more source
根据±800 kV特高压直流输电工程中支持平波电抗器用支柱瓷绝缘子机械、电气、耐地震等性能的要求,较详细地介绍了±800 kV直流系统中平波电抗器用支柱瓷绝缘子的产品设计、试制及试验等研制情况,支柱瓷绝缘子的污秽外绝缘设计,瓷外表面PRTV涂层的特点、优点,耐地震计算分析和性能评价。试验结果表明,所研制绝缘子的机械、电气等特性均能满足±800 kV特高压直流输电工程的要求。还介绍了向家坝-上海±800 kV特高压直流输电工程中平波电抗器用支柱瓷绝缘子及不同电压等级棒形支柱瓷绝缘子在直流场中的应用。
周军
doaj
换流阀是特高压直流输电工程中主要关键设备,其设计的可靠性直接影响直流系统的安全可靠运行。文中介绍了锦屏—苏南±800 kV特高压直流工程晶闸管换流阀主要技术参数。主要从电压应力、电流应力、水冷系统、晶闸管参数4个方面和先前投运的向家坝—上海±800 kV特高压直流工程晶闸管换流阀进行了对比分析。验证了锦屏—苏南特高压直流工程晶闸管换流阀整体性能比向家坝—上海±800 kV直流工程有所提升,可以长期安全可靠运行;同时也为后续±800 kV特高压直流工程换流阀的设计和制造奠定了良好的基础。
娄彦涛, 马元社, 刘飞, 高奇
doaj
介绍了已研发成功,并具有国际领先水平的800 kV双断口罐式断路器的设计、试验过程,重点对800 kV双断口罐式断路器开发中的技术课题及其应对措施进行详细介绍。
南振乐 +5 more
doaj
当±800 kV新东直流正常运行时,±800 kV昆柳龙线路与其部分线段并行,昆柳龙线路感应电压远远高于其他直流线路感应电压。文中利用有限元仿真软件建立新东直流和昆柳龙直流并行线段的二维仿真计算模型,仿真了新东直流输电线路带电运行情况下昆柳龙直流线路的感应电压特性。结果表明:柳北站—龙门站线路在静电场单独作用下,正极感应电压为6 kV,负极感应电压12 k V;在静电场与离子流场的合成电场作用下,正极感应电压为20.7 kV,负极感应电压30.5 kV,这与实际测量结果最高感应电压为42 kV较为接近 ...
杨晓峰 +7 more
doaj
Dielectric constant of glasses: first observation of a two-dimensional behavior
The 1kHz real part $\chi'$ of the dielectric constant of a structural glass was measured at low temperature $T$ down to 14 mK. Reducing the sample thickness $h$ to 10 nm suppresses the usual minimum of $\chi'$ for measuring fields ...
F. Ladieu +8 more
core +3 more sources
ZF27-800型GIS是为满足我国西北750 kV输电工程自主研发的800 kV气体绝缘金属封闭开关设备。笔者介绍了ZF27-800型GIS的研制情况,主要对800kV断路器的开断系统、绝缘系统、传动系统和动力系统的关键技术进行了分析,还对GIS中的母线、进出线套管的设计技术进行了说明。
韩国辉, 谭盛武, 韩书谟
doaj
Seismic evaluation of ±800 kV UHVDC disconnect switch by shake table test
Disconnect switches, the widely used electrical substation apparatuses, however, were severely damaged in several earthquakes, causing huge economic losses.
Jiayi Wen, Qiang Xie
doaj +1 more source
A Multi Megawatt Cyclotron Complex to Search for CP Violation in the Neutrino Sector
A Multi Megawatt Cyclotron complex able to accelerate H2+ to 800 MeV/amu is under study. It consists of an injector cyclotron able to accelerate the injected beam up to 50 MeV/n and of a booster ring made of 8 magnetic sectors and 8 RF cavities.
Calabretta, L. +4 more
core