Results 31 to 40 of about 1,979,787 (310)

Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study. [PDF]

open access: yes, 2015
BACKGROUND: Spiromax® is a novel dry-powder inhaler containing formulations of budesonide plus formoterol (BF). The device is intended to provide dose equivalence with enhanced user-friendliness compared to BF Turbuhaler® in asthma and chronic ...
Philip Chetcuti   +9 more
core   +2 more sources

Inhalation studies with the Göttingen minipig

open access: yes, 2022
S.249-259A method for inhalative exposure of minipigs to aerosols and gases has been developed. Minipigs are exposed via mask inhalation to the test substance using a computer-controlled exposure system that permits simultaneous exposure of groups of ...
Windt, H.   +4 more
core   +1 more source

¿Son eficaces los corticoides inhalados en las exacerbaciones asmáticas? Evidentia praxis

open access: yesAnales de Pediatría, 2021
Resumen: Se presenta un escenario clínico del que surge una pregunta clínica estructurada: en niños o adolescentes asmáticos con síntomas de exacerbación, ¿el uso de corticoides inhalados (de nueva instauración o aumento de dosis habitual) reduce el ...
Carlos Ochoa Sangrador   +2 more
doaj   +1 more source

Improved Metered Dose Inhaler Technique When a Coordination Cap Is Used [PDF]

open access: yes, 2014
Background: Patients often experience problems using metered dose inhalers (MDIs), particularly poor coordination between inhalation start and dose actuation (TsIn: time difference between the start of an inhalation and the actuation of a dose), and fast
Stephenson, John   +9 more
core   +1 more source

A statistical evaluation of the effects of gender differences in assessment of acute inhalation toxicity [PDF]

open access: yes, 2011
Acute inhalation toxicity of chemicals has conventionally been assessed by the median lethal concentration (LC50) test (organisation for economic co-operation and development (OECD) TG 403).
Price, Charlotte   +13 more
core   +1 more source

Comparison of the Pulmonary Oxidative Stress Caused by Intratracheal Instillation and Inhalation of NiO Nanoparticles when Equivalent Amounts of NiO Are Retained in the Lung

open access: yesAntioxidants, 2016
NiO nanoparticles were administered to rat lungs via intratracheal instillation or inhalation. During pulmonary toxicity caused by NiO nanoparticles, the induction of oxidative stress is a major factor.
Masanori Horie   +10 more
doaj   +1 more source

Evaluation of asthma control, parents’ quality of life and preference between AeroChamber Plus and AeroChamber Plus Flow-Vu spacers in young children with asthma [PDF]

open access: yes, 2015
Objective: The AeroChamber Plus (AC) valved holding chamber has been enhanced to include the Flow-Vu (FV) inspiratory flow indicator that provides visual inhalation feedback during use. We have investigated if FV alters asthma control and whether parents
Toor, Sophie   +4 more
core   +1 more source

Pulmonary toxicity of printer toner following inhalation and intratracheal instillation

open access: yes, 2022
S.679-690The pulmonary effects of a finished toner were evaluated in intratracheal instillation and inhalation studies, using toners with external additives (titanium dioxide nanoparticles and amorphous silica nanoparticles).
Morimoto, Yasuo   +11 more
core   +1 more source

Clinical efficacy of dexmedetomidine combined with sevoflurane sedation in pediatric MRI scanning

open access: yesDi-san junyi daxue xuebao, 2020
Objective To observe the sedation effect and safety of intranasal dexmedetomidine in combination with sevoflurane inhalation for pediatric patients undergoing magnetic resonance imaging(MRI).
ZHANG Tiange   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy