Improved DFIG Capability during Asymmetrical Grid Faults [PDF]
In the wind power application, different asymmetrical types of the grid fault can be categorized after the Y/d transformer, and the positive and negative components of a single-phase fault, phase-to-phase fault, and two-phase fault can be summarized. Due
Blaabjerg, Frede, Zhou, Dao
core +6 more sources
Synchronous Power Control of Grid-Connected Power Converters under Asymmetrical Grid Fault [PDF]
Control of grid-connected power converters is continuously developing to meet the grid codes, according to which the generation units should keep connected to the grid and further provide ancillary services, such as voltage and frequency support ...
Weiyi Zhang +3 more
doaj +3 more sources
Fault coordination control for converter-interfaced sources compatible with differential protection during asymmetrical faults [PDF]
Converter-interfaced renewable energy sources (CIRESs) may have a different fault current angle with synchronous generators (SGs), so the large angle difference on both sides will cause low sensitivity or failure for traditional proportional braking ...
Zhe Yang +3 more
doaj +3 more sources
Study on fracture development and failure characteristics of repeated mining overlying strata in multi-coal seams with faults [PDF]
Taking a mine in Guizhou Province as the research background, a combination of similar simulation experiments and numerical simulation was used to analyse the spatial distribution of overburden collapse and the development of fissures during the mining ...
Baoyan Zhi +6 more
doaj +2 more sources
Active fault tolerant control for twin wind turbine subject to asymmetric fault [PDF]
This paper addresses the problem of control of a twin wind turbine which is subject to an electrical fault affecting only one stator phase of one turbine. An active fault tolerant control is proposed. The performance and robustness of the proposed control, comparing to a passive fault tolerant one developed in the literature, are shown through ...
Makni, Mariem +5 more
openaire +3 more sources
Stator faults are the most critical faults in induction motors as they develop quickly hence requiring fast online diagnostic methods. A number of online condition monitoring techniques are proposed in the literature to respond to such faults, including ...
Syaiful Bakhri, Nesimi Ertugrul
doaj +1 more source
Simulation-based post-fault analysis in WECS using DFIG systems under an unbalanced fault scenario
Fault analysis in an integrated Wind Energy Conversion System (WECS) is the highest priority factor to be taken into account for distributed generation (DG).
Muzamil Hussain Wadho +3 more
doaj +1 more source
The increasing share of converter-based renewable energy sources in the power system has forced the system operators to demand voltage support from the converters in case of faults.
Muhammad Abubakar +2 more
doaj +1 more source
Development of a Novel Control Scheme for Grid-Following Converter under Asymmetrical Faults
With the increasing penetration of converter-based power sources into the power system, the performance of the converter has become a key factor for enhancing grid reliability, especially during asymmetrical faults.
Muhammad Abubakar +2 more
doaj +1 more source
Assessing Asymmetric Fault-Tolerant Software [PDF]
The most popular forms of fault tolerance against design faults use "asymmetric" architectures in which a "primary" part performs the computation and a "secondary" part is in charge of detecting errors and performing some kind of error processing and recovery. In contrast, the most studied forms of software fault tolerance are "symmetric" ones, e.g.
Popov, P. T., Strigini, L.