Simulation Analysis of Grounding Characteristics of Cable Based on ATP-EMTP

open access: yesIEEE Access, 2022
In order to improve the operational safety and stability of power cables, it is necessary to conduct targeted research on different grounding modes. Firstly, the appropriate cable parameters were selected according to the specific use, and the model was established in ATP-EMTP according to the selected cable parameters.
Youcong Huang   +6 more
openaire   +3 more sources

Optimization of dynamic MOSA model parameters using ATP/EMTP software tool [PDF]

open access: yesZbornik radova, Elektrotehnicki institut Nikola Tesla, 2017
This paper demonstrates the procedure for estimating parameters of a dynamic metal-oxide surge arrester model by using a genetic algorithm, implemented in ATP/EMTP graphic preprocessor (ATPDraw) optimization module. The advantages of new ATPDraw options that allow optimization of electric circuit elements are shown.
Jasika Ranko   +3 more
openaire   +3 more sources

Studi Pemasangan Damping Reaktor untuk Mengatasi Feroresonansi pada Incoming 20 KV GIS Tandes [PDF]

open access: yesJurnal Teknik ITS, 2015
Pada studi ini, dilakukan simulasi pemasangan damping reaktor sebagai salah satu teknik mitigasi feroresonansi dengan menggunakan ATP Draw. Damping reaktor sebagai teknik mitigasi feroresonansi menggunakan elemen resistor yang dipasang di sisi primer ...
Fahmi, D. (Daniar)   +2 more
core   +3 more sources

Application of the Heidler function in electromagnetic transients programs [PDF]

open access: yesZbornik Radova: Elektrotehnički Institut "Nikola Tesla", 2021
The paper analyzes the possibility of using the Heidler function in programs for electromagnetic transients. The parameters of the Heidler function are calculated for various standard waveforms, where greater accuracy is shown for certain waves than with
Mrvić Jovan   +2 more
doaj   +1 more source

Research on VFTO Identification of GIS Based on Wavelet Transform and Singular Value Decomposition

open access: yesEnergies, 2022
The accurate identification of Very Fast Transient Overvoltage (VFTO) is the key of overvoltage control in modern smart grids. In order to accurately identify VFTO generated by the operation of a disconnector in Gas Insulated Substation (GIS), a VFTO ...
Gang Xiao   +7 more
doaj   +1 more source

Using alternative transient program and electromagnetic transients programs (ATP/EMTP) in lightning overvoltages analysis [PDF]

open access: yesZbornik Radova: Elektrotehnički Institut "Nikola Tesla", 2016
The goal of this paper is to introduce a procedure for risk assessment of insulation failure due to storm surges. The simulations were carried out in ATP / EMTP software, which allowed the use of the Monte Carlo method for the statistical analysis of ...
Mrvić Jovan   +4 more
doaj   +1 more source

Lightning protection for power transformers of Aqaba Thermal Power Station

open access: yesArchives of Electrical Engineering, 2020
In this paper, a study of the lightning phenomenon and its harmful effect on Aqaba Thermal Power Station (ATPS), located in the south-western border of Jordan, is presented using the Electromagnetic Transients Program – Alternative Transients Program ...
Wael Fawzi Abu Shehab   +2 more
doaj   +1 more source

Reducing the Effect of Lightning on Step and Touch Voltages in a Grounding Grid Using a Nature-Inspired Genetic Algorithm With ATP-EMTP

open access: yesIEEE Access, 2019
This paper discusses the step and touch voltages, based on body resistance, in a grounding grid after a lightning strike at a 434-/21-kV substation. To ensure grounding grid safety, the maximum step and touch voltage should not exceed the safety criteria
Saeid Gholami Farkoush   +5 more
doaj   +1 more source

Simulation Analysis of Three Phase Unbalanced Current and Over Compensation of High Voltage Reactor in Transmission Line

open access: yes南方能源建设, 2021
[Introduction] The safe and stable operation of UHV transmission lines is essential to the safety of power grids. When the new substation deconstructs the original long line in the power grid planning and construction, the following problems, such as the
ZHENG Xing, CHEN Yipeng, QI Donghui
doaj   +1 more source

Identify Direct Lightning Strike Location Based on Discrete Wavelet Transform for 115-kV Transmission System

open access: yesIEEE Access, 2022
This paper proposes three techniques for locating lightning strikes in a 115 kV transmission system over 88.5 km, based on the arrival time of a transient wave obtained from a discrete wavelet transform (DWT).
Pathomthat Chiradeja   +1 more
doaj   +1 more source