Results 91 to 100 of about 912,461 (203)

Composition of allogeneic equine orthobiologics and their repeated intra‐articular administrations

open access: yesEquine Veterinary Journal, EarlyView.
Abstract Background Orthobiologics such as platelet‐rich plasma (PRP) and alpha‐2‐macroglobulin (A2MG) are increasingly used for equine musculoskeletal injuries. However, their composition and safety with repeated allogeneic intra‐articular administration remain poorly investigated.
Yanne Van Reusel   +7 more
wiley   +1 more source

High-Throughput Automated Luminescent Magnetic Particle-Based Immunoassay to Monitor Human Exposure to Pyrethroid Insecticides

open access: yes, 2016
We have developed a sensitive, automated, competitive chemiluminescent immunoassay for the detection of 3-phenoxybenzoic acid (3-PBA), a metabolite common to many pyrethroid insecticides.
Bruce D. Hammock (65754)   +5 more
core   +1 more source

Prevalence of insulin dysregulation in a sport horse population as determined by traditional and stall‐side testing

open access: yesEquine Veterinary Journal, EarlyView.
Abstract Background The prevalence of insulin dysregulation (ID) has not been investigated in sport horses. Stall‐side insulin assays offer convenience but need further validation. Objectives To determine the prevalence of and risk factors for ID in a sport horse population using an oral sugar test (OST) and assess agreement between stall‐side and ...
Kimberly L. Hallowell   +7 more
wiley   +1 more source

Lab-on-chip system combining a microfluidic-ELISA with an array of amorphous silicon photosensors for the detection of celiac disease epitopes

open access: yesSensing and Bio-Sensing Research, 2015
This work presents a lab-on-chip system, which combines a glass-polydimethilsiloxane microfluidic network and an array of amorphous silicon photosensors for the diagnosis and follow-up of Celiac disease. The microfluidic chip implements an on-chip enzyme-
Francesca Costantini   +6 more
doaj   +1 more source

Enzyme immunoassay kits used (Peninsula Laboratories Inc.).

open access: yes, 2018
Enzyme immunoassay kits used (Peninsula Laboratories Inc.).
Piotr Podlasz (5309672)   +5 more
core   +1 more source

Evaluation of a new immunoassay for measuring equine serum insulin and plasma adrenocorticotrophic hormone: A method comparison study

open access: yesEquine Veterinary Journal, EarlyView.
Abstract Background Insulin dysregulation (ID) and pituitary pars intermedia dysfunction (PPID) are common equine endocrinopathies detected by measurement of circulating insulin and adrenocorticotrophic hormone (ACTH) concentrations. Different assays may yield variable results, limiting comparability.
Nicola J. Menzies‐Gow   +2 more
wiley   +1 more source

Ultrasensitive enzyme immunoassay

open access: yes, 1990
Ultrasensitive enzyme immunoassay methods not only for antigens but also for antibodies and haptens are reviewed. These methods are based on a noncompetitive type of assay using solid phase rather than a competitive one.
Eiji Ishikawa Seiichi Hashida   +1 more
core  

Illuminating point‐of‐care diagnostics with aggregation‐induced emission biosensors

open access: yesFlexMat, EarlyView.
This review highlights the application of aggregation‐induced emission luminogens (AIEgens) in point‐of‐care (POC) diagnostics for disease biomarker detection. It systematically examines a range of biosensing platforms, including lateral flow immunoassays, microfluidic chips, and electrochemiluminescence sensors, alongside their utility in detecting ...
Danni Hu   +3 more
wiley   +1 more source

Diagnostic performance of tumor markers AFP and PIVKA-II in Chinese hepatocellular carcinoma patients

open access: yesTumor Biology, 2017
Alpha-fetoprotein is an effective biomarker as an aid in hepatocellular carcinoma detection in many countries. However, alpha-fetoprotein has its limitations, especially in early hepatocellular carcinoma diagnosis. Protein induced by vitamin K absence or
Shujing Huang   +7 more
doaj   +1 more source

Automation vs. Experience: Measuring Alzheimer’s Beta-Amyloid 1–42 Peptide in the CSF

open access: yesFrontiers in Aging Neuroscience, 2018
Cerebrospinal fluid (CSF) biomarkers can enhance the early and accurate etiologic detection of Alzheimer’s disease (AD) even when symptoms are very mild, but are not yet widely available for clinical testing.
Alexander L. Kollhoff   +2 more
doaj   +1 more source