Results 1 to 10 of about 433,541 (264)
Monitoring Knee Contact Force with Force-Sensing Insoles [PDF]
Numerous applications exist for monitoring knee contact force (KCF) throughout activities of daily living. However, the ability to estimate these forces is restricted to a laboratory setting.
Alex Spencer +2 more
doaj +4 more sources
Event Augmentation for Contact Force Measurements
Neuromorphic vision sensor is an attractive technology that offers high dynamic range, and low latency which are crucial in robotic applications. However, the lack of event-based data in this field, limits the sensors’ performance in a real-world ...
Fariborz Baghaei Naeini +3 more
doaj +2 more sources
Aim To evaluate healthcare provider awareness and uptake of the Centers for Medicare & Medicaid Services (CMS) billing for coronavirus disease 2019 (COVID‐19) prevention counselling and the delivery of prevention counselling to patients awaiting severe ...
Melanie M. Taylor +13 more
doaj +1 more source
Development of a Contact Force Model Suited for Spherical Contact Event
The stiffness coefficient suited for a spherical contact body is developed by means of a contact semi-angle based on Steuermann’s theory. The new static contact force model is close to the results of FEM when the index of the polynomial is equal to 2 ...
Siyuan Wang, Peng Gao
doaj +1 more source
This paper describes the relationship between a tangential contact force and a slip ratio under various wet condition. In previous studies, the effect of difference in watering amount on the tangential contact force characteristics under wheel/rail ...
Daisuke YAMAMOTO
doaj +1 more source
Stator-Rotor Contact Force Estimation of Rotating Machine
In turbomachines, dry friction resulting from stator–rotor contacts is a severe problem that may degrade lifetime of the machine or even lead to complete failure. Knowledge about the system states and contact forces is beneficial for system monitoring or
Mark Spiller, Dirk Söffker
doaj +1 more source
Formation behavior of bubbles and its effect on strength in PET/SUS304 dissimilar materials laser spot lap joint was studied. Surface of SUS304 was irradiated through transparent PET with fiber laser.
Yukio MIYASHITA +2 more
doaj +1 more source
Assessment of ablation catheter contact on valve annulus: Implications on accessory pathway ablation
Background: Catheter-tissue contact force is an important factor influencing lesion size and efficacy and thereby potential for arrhythmia recurrence following accessory pathway (AP) radiofrequency ablation.
Wai Kah Choo +7 more
doaj +1 more source
To explore the accuracy of the calculation method of the jacking force of circular curved pipe jacking under different pipe-soil contact characteristics, in combination with the curved steel pipe jacking project of Gongbei Tunnel of Hong Kong-Zhuhai ...
Yuheng Zhou +4 more
doaj +1 more source
A continuous contact force model of planar revolute joint based on fitting method
Both the process of eliminating the clearance in joints and the contact–impact process involve movement of a clearance mechanism, which may reduce transmission accuracy and lengthen the response time. An appropriate continuous contact force model is able
Yuntao Li +4 more
doaj +1 more source

