Results 31 to 40 of about 4,312,222 (304)
Validation of the accuracy of contact force measurement by contemporary force-sensing ablation catheters. [PDF]
INTRODUCTION Contact force-sensing catheters are widely used for ablation of cardiac arrhythmias. They allow quantification of catheter-to-tissue contact, which is an important determinant for lesion formation and may reduce the risk of complications.
Knecht, Sven +19 more
core +2 more sources
Assessment of ablation catheter contact on valve annulus: Implications on accessory pathway ablation
Background: Catheter-tissue contact force is an important factor influencing lesion size and efficacy and thereby potential for arrhythmia recurrence following accessory pathway (AP) radiofrequency ablation.
Wai Kah Choo +7 more
doaj +1 more source
Research on time–frequency characteristics of contact force based on wavelet transform
When a train runs at high speed, affected by the structural characteristics of the catenary, the contact force changes periodically with span and dropper spacing.
Fang He, Jian Zhang
doaj +1 more source
Forcing contact inhibition of locomotion
Contact inhibition of locomotion drives a variety of biological phenomenon, from cell dispersion to collective cell migration and cancer invasion. New imaging techniques have allowed contact inhibition of locomotion to be visualised in vivo for the first time, helping to elucidate some of the molecules and forces involved in this phenomenon.
Roycroft, A, Mayor, R
openaire +3 more sources
Estimation of contact forces using a virtual force sensor [PDF]
Physical human-robot collaboration is character- ized by a suitable exchange of contact forces between human and robot, which can occur in general at any point along the robot structure. If the contact location and the exchanged forces were known in real time, a safe and controlled collaboration could be established.
MAGRINI, EMANUELE +2 more
openaire +3 more sources
The metal contact is one of the most crucial parts in ohmic-contact microelectromechanical (MEMS) switches, as it determines the device performance and reliability.
Haodong Qiu, Hong Wang, Feixiang Ke
doaj +1 more source
A learning-based tip contact force estimation method for tendon-driven continuum manipulator
Although tendon-driven continuum manipulators have been extensively researched, how to realize tip contact force sensing in a more general and efficient way without increasing the diameter is still a challenge. Rather than use a complex modeling approach,
Fan Feng, Wuzhou Hong, Le Xie
doaj +1 more source
This paper describes a practical wheel/rail tangential contact force model for railway dynamics analysis under running in rainy conditions. In our previous studies, it was confirmed that experimental results of tangential contact force measurement are ...
Daisuke YAMAMOTO
doaj +1 more source
Knee adduction moment and medial contact force - facts about their correlation during gait [PDF]
The external knee adduction moment is considered a surrogate measure for the medial tibiofemoral contact force and is commonly used to quantify the load reducing effect of orthopedic interventions. However, only limited and controversial data exist about
Bergmann, Georg +11 more
core +1 more source
The contact resistance performance of gold coated carbon-nanotube surfaces under low current switching [PDF]
Multi-Walled CNT (MWCNT) are synthesized on a silicon wafer and sputter coated with a gold film. The planar surfaces are mounted on the tip of a piezo-electric actuator and mated with a gold coated hemispherical surface to form an electrical contact ...
Chianrabutra, Chamaporn +3 more
core +1 more source

