Results 81 to 90 of about 1,072,644 (295)

Calibrating canines—a universal detector calibrant for detection dogs

open access: yesFrontiers in Allergy
Since the advent of the Universal Detector Calibrant (UDC) by scientists at Florida International University in 2013, this tool has gone largely unrecognized and under-utilized by canine scent detection practitioners. The UDC is a chemical that enables reliability testing of biological and instrumental detectors. Training a biological detector, such as
Michele N. Maughan   +10 more
openaire   +3 more sources

Identifying and characterising a plant GH1 β‐glucosidase that exhibits hydrolytic activity on N‐linked glucopyranoside

open access: yesFEBS Open Bio, EarlyView.
We report the first β‐glucosidase with demonstrated hydrolytic activity on an N‐linked glycopyranoside. The enzyme, native to maize, was biochemically characterised for this novel reaction, and structural modelling of the enzyme–substrate complex revealed several clues to the underlying reduced catalytic rate relative to its native O‐glycopyranoside ...
Hani Gharabli   +3 more
wiley   +1 more source

De novo synthesis of short‐chain aldehydes and hydrocarbons secreted by the brown marmorated stink bug Halyomorpha halys

open access: yesFEBS Open Bio, EarlyView.
The brown marmorated stink bug, Halyomorpha halys, mainly secretes 4‐oxo‐(E)‐2‐hexenal, (E)‐2‐decenal, dodecane and tridecane, a mixture representative of that released by many heteropterans. We demonstrated that H. halys can synthesise these secretory components de novo using dietary glucose.
Haruna Fujimori, Koji Noge
wiley   +1 more source

Research on Calibration Method of Relative Detection Efficiency for Large Number of 3He Detector

open access: yesYuanzineng kexue jishu, 2022
In the development of some equipments or in the production environment of specific fissionable nuclear materials, neutron flux distribution measurements are required using a large number of neutron detectors to determine the production status.
YU Jialei;HOU Long;WANG Qi;SUN Qi;ZHU Qingfu
doaj  

Calibration and Readiness of the ISS-RAD Charged Particle Detector [PDF]

open access: yes, 2015
The International Space Station (ISS) Radiation Assessment Detector (RAD) is an intravehicular energetic particle detector designed to measure a broad spectrum of charged particle and neutron radiation unique to the ISS radiation environment.
Rios, R.
core  

A robust chessboard detector for geometric camera calibration

open access: yes, 2022
S.34-43We introduce an algorithm that detects chessboard patterns in images precisely and robustly for application in camera calibration. Because of the low requirements on the calibration images, our solution is particularly suited for endoscopic camera
Hettenkofer, Sebastian   +4 more
core   +1 more source

Protocol for quantifying miRNA trafficking across the endosomal membrane

open access: yesFEBS Open Bio, EarlyView.
An in vitro protocol measures miRNA uptake into endosomes isolated from mammalian cell extracts, which are free of subcellular contaminants. Performed at 37 °C in the presence of ATP, it ensures the import of single‐stranded miRNA into the endosomal lumen.
Syamantak Ghosh   +2 more
wiley   +1 more source

Development and Validation of a Digitizer-Based TCSPC System for Scintillation Decay Time Analysis via an Extended Convolution Model

open access: yesSensors
The development of high-fidelity digital twins for scintillation spectrometer detectors demands precise experimental characterization of timing parameters.
Qianqian Zhou   +4 more
doaj   +1 more source

GelMA‐based 3D spheroids recapitulate transcriptomic and functional hallmarks of myeloid sarcoma

open access: yesFEBS Open Bio, EarlyView.
GelMA 5% hydrogels support the formation of myeloid leukemia spheroids that recapitulate MS‐specific features, including G1 arrest, apoptosis, and ECM‐driven transcriptomic reprogramming. The 3D model mimicked soft‐tissue‐like stiffness and oxygen conditions, and transcriptomic convergence with primary MS samples confirmed its utility as a preclinical ...
Nicolas Germain   +11 more
wiley   +1 more source

Detector-based absolute radiometric calibration of lamps and reflectance panels

open access: yes, 1991
The absolute calibration of remote sensing systems is based upon radiometric standards. The irradiance standards are currently 1000-watt quartz tungsten-halogen lamps that are traced to National Institute of Standards and Technology standards by a middle
Penny, Iain Reynold, 1966-
core   +3 more sources

Home - About - Disclaimer - Privacy