Results 241 to 250 of about 92,932 (296)
Letter Distortion Mapping in Amblyopia: Spatial Patterns, Stability, and Relationship to Visual Acuity. [PDF]
Molaei H, Abbas Farishta R, Farivar R.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Measurement of Voltage, Current and Power at Distorted Waveforms
IEEE Instrumentation & Measurement Magazine, 2021Electric power systems have been designed to operate under sinusoidal voltage and current conditions at power frequencies, mainly 50 Hz and 60 Hz, and by far most electrical energy transmission occurs at 50 Hz and 60 Hz. Electric utilities are responsible for providing a sinusoidal voltage to their residential, commercial and industrial customers.
Djokic, Branislav, Parks, Harold
openaire +2 more sources
Assessment and Treatment of Distorted Schemas in Sexual Offenders
The aim of this review is to examine the literature related to the assessment and treatment of sex offenders’ distorted schemas. Where appropriate, the review draws upon current insights from the field of social cognition to aid in the critical ...
Anthony R Beech +2 more
exaly +4 more sources
Cochlear Distortion: Effect of Direct-Current Polarization
Science, 1969Intermodulation components (combination tones) appearing in microphonic potentials were measured from guinea pig cochleas with and without polarizing direct currents passing through the cochlear partition. At moderate intensities of stimulus the polarization had a qualitatively different effect on the distortion components than on their eliciting ...
P, Dallos +3 more
openaire +2 more sources
Characterization of Current Transformers in the Presence of Harmonic Distortion
2008 IEEE Instrumentation and Measurement Technology Conference, 2008The CTs performance under distorted conditions are usually characterized by means of the frequency response test. In this paper a new way to characterize CTs, closer to real operative conditions, is proposed. The harmonic phase angle and ratio errors are measured when the CTs are excited with a nonsinusoidal current composed of a fundamental and one ...
Cataliotti A +4 more
openaire +1 more source
Intermodulation distortion in current-commutating CMOS mixers
IEEE Journal of Solid-State Circuits, 2000The nonlinearity behavior of CMOS current-switching mixers is investigated. By treating the mixer as a periodically-time-varying weakly nonlinear circuit, we study the distortion-causing mechanisms and we predict the mixer distortion performance. Normalized graphs are provided from which the designer can readily estimate the mixer nonlinearity for ...
Manolis Terrovitis, Robert G. Meyer
openaire +1 more source
The Measurement of Distortion Current and Distortion Power
IEEE Transactions on Instrumentation and Measurement, 1984A converter for resolving current or voltage into three mutually orthogonal components-active, reactive, and distortion-is suggested. The described system confirms the possibility of measuring the distortion current and distortion power on the basis of the time-domain approach.
openaire +2 more sources

