Results 71 to 80 of about 41,874 (287)

IMPEDANCE ANALYSIS FOR FOUR TYPES OF MINERAL WATER AND AQUADES USING ELECTRICAL IMPEDANCE SPECTROSCOPY (EIS) AT FREQUENCIES OF 1 Hz - 50 kHz

open access: yesIndonesian Physical Review, 2023
The Electrical Impedance Spectroscopy (EIS) method can be used to identify minerals in mineral water. The EIS method measures the impedance of a material by injecting alternating current in a certain frequency range, which is non-invasive and non-destructive.
Darmawati Wulandari   +2 more
openaire   +1 more source

Highly Sensitive Electrochemical Biosensor Based on Hairy Particles with Controllable High Enzyme Loading and Activity

open access: yesAdvanced Functional Materials, EarlyView.
For the first time, a highly sensitive electrochemical biosensor based on SiO2‐based hairy particles with a grafted PDMAEMA polymer brush containing a quantifiable and large amount of immobilized Laccase is reported. The fabricated biosensor exhibits a sensitivity of 0.14 A·m⁻¹, a limit of detection (LOD) of 0.1 µm, and a detection range of 0.3–750 µm,
Pavel Milkin   +7 more
wiley   +1 more source

Mediator-free interaction of glucose oxidase, as model enzyme for immobilization, with Al-doped and undoped ZnO thin films laser-deposited on polycarbonate supports [PDF]

open access: yes, 2017
Al doped and undoped ZnO thin films were deposited by pulsed-laser deposition on polycarbonate sheets. The films were characterized by optical transmission, Hall effect measurement, XRD and SEM.
Inguva, Saikumar   +5 more
core   +1 more source

3D‐Printed Sulfur‐Derived Polymers With Controlled Architectures for Lithium‐Sulfur Batteries

open access: yesAdvanced Functional Materials, EarlyView.
Rheology‐guided formulation design for direct ink writing enables the fabrication of 3D sulfur copolymer cathodes with controlled architectures for lithium‐sulfur batteries. The printed electrodes exhibit multiscale porosity and high sulfur utilization, delivering enhanced electrochemical performance compared to conventional cast electrodes.
Bin Ling   +7 more
wiley   +1 more source

Circuital modelling in muscle tissue impedance measurements

open access: yesHeliyon
Electrical impedance spectroscopy (EIS) stands as a widely employed characterization technique for studying muscular tissue in both physio/pathological conditions. This methodology commonly involves modeling tissues through equivalent electrical circuits,
Fabrizio Clemente   +6 more
doaj   +1 more source

Investigating Electrical Impedance Spectroscopy for Estimating Blood Flow-Induced Variations in Human Forearm

open access: yesSensors, 2020
This work aims to investigate the feasibility of employing multi-frequency bioimpedance analysis for hemodynamic assessment. Towards this, we aim to explore one of its implementations, electrical impedance spectroscopy (EIS), for estimating changes in ...
Gautam Anand, Andrew Lowe
doaj   +1 more source

Triethylphosphite as a network forming agent enhances in-vitro biocompatibility and corrosion protection of hybrid organic-inorganic sol-gel coatings for Ti6Al4V alloys [PDF]

open access: yes, 2014
The biocompatibility and life of metallic implants can be enhanced through improving the biocompatibility and corrosion protection characteristics of the coatings used with these materials.
Barranco, V   +5 more
core   +3 more sources

PEDOT‐Based Eutectogel Electrode Arrays for Enhanced High‐Resolution Electrogastrography: Fabrication, Stability, and Wearable Performance

open access: yesAdvanced Functional Materials, EarlyView.
Here, we present a high‐density PEDOT eutectogel electrode array for enhanced body surface gastric mapping. Silver electrodes are blade‐coated onto flexible substrates, followed by electrogelation of PEDOT:PSS and the deposition of a PEDOT:LS eutectogel.
Christopher Slaughter   +8 more
wiley   +1 more source

Limits on the use of cobalt sulfide as anode of p-type dye-sensitized solar cells [PDF]

open access: yes, 2017
Thin films of cobalt sulfide (CoS) of thickness l < 10m have been employed as anodes of p-type dye-sensitized solar cells (p-DSCs) when P1-sensitized nickel oxide (NiO) was the photoactive cathode and /I - constituted the redox mediator.
Bonomo, Matteo   +6 more
core   +2 more sources

Regiorandom Polythiophenes for Fully Stretchable Electrochemical Transistors and Logic Circuits

open access: yesAdvanced Functional Materials, EarlyView.
Regiorandom (RRa) polythiophenes, once regarded as unsuitable for electronics, exhibit exceptional switching performance via volumetric electrochemical doping. Optimized RRa‐based organic electrochemical transistors (OECTs) achieve a high on/off ratio (≈104), stable operation under 200% strain, and enable fully stretchable logic gates, demonstrating ...
Dong Hyun Park   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy