Results 31 to 40 of about 1,197,587 (258)

Base Plate Corrosion and Premature Bearing failure in RO Pump [PDF]

open access: yes, 2018
Case StudiesOn 19th Aug 2017, abnormal noise noticed from RO (Reverse osmosis) Membrane Feed pump coupling area. Checked the vibration for pump & motor and found very high vibration at Pump Drive end. The vibration level at Pump DE Vertical recorded as 4.
Subramanian, Moorthy
core   +1 more source

3-D Finite Element Model for Drum-Type HTS Dynamos

open access: yesIEEE Access
Continuous cylindrical stator high-temperature superconducting (HTS) dynamos, also known as drum-type HTS dynamos, are devices for contactless current injection, but their complex three-dimensional (3D) electromagnetic behaviour cannot be captured ...
Mujtaba Hussain   +8 more
doaj   +1 more source

A New Method of Selecting the Airlift Pump Optimum Efficiency at Low Submergence Ratios with the Use of Image Analysis

open access: yesEnergies, 2019
This paper presents experimental studies on the optimization of two-phase fluid flow in an airlift pump. Airlift pumps, also known as mammoth pumps, are devices applied for vertical transport of liquids with the use of gas.
Grzegorz Ligus   +3 more
doaj   +1 more source

Study on the influence of dynamic/static interface processing methods on CFD simulation results of the axial-flow blood pump

open access: yesAdvances in Mechanical Engineering, 2020
Computational fluid dynamics is an essential tool for the flow field analysis of the blood pump. The interface processing method between the dynamic/static regions will affect the accuracy of simulation results, but its influence on the simulation ...
Shuai Wang, Jianping Tan, Zheqin Yu
doaj   +1 more source

Recip Pump on Unstable Condensate [PDF]

open access: yes, 2018
Case StudiesPump Design Conditions, Sealing/Packing System Design Features, Sealing/Packing System Failures, Pump Improvements, Conclusions and Lessons ...
Mascherpa, Luigi, Jakubiak, Jason
core   +1 more source

High-harmonic generation in CdTe with ultra-low pump intensity and high photon flux

open access: yesCommunications Physics, 2023
An ultra-low pump intensity and high photon flux have been long pursuits of high harmonic generation (HHG) in solids. However, there is lack of a criterion to identify a pristine solid material exhibiting such characteristics.
Zhe Long   +7 more
doaj   +1 more source

Exercise Capacity, Physical Activity, Fatigue, and Neurocognitive Function in Adult Survivors of Childhood Acute Lymphoblastic Leukemia

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Adult survivors of childhood acute lymphoblastic leukemia (ALL) are at risk of reduced exercise capacity, decreased physical activity levels, persistent fatigue, and neurocognitive deficits. The aim was to investigate exercise capacity and physical activity levels of adult survivors of childhood ALL and their associations with ...
Laura Jess   +5 more
wiley   +1 more source

Comparative CO2 flux measurements by eddy covariance technique using open- and closed-path gas analysers over the equatorial Pacific Ocean [PDF]

open access: yesTellus: Series B, Chemical and Physical Meteorology, 2012
Direct comparison of air–sea CO2 fluxes by open-path eddy covariance (OPEC) and closed-path eddy covariance (CPEC) techniques was carried out over the equatorial Pacific Ocean.
Fumiyoshi Kondo, Osamu Tsukamoto
doaj   +1 more source

High Vibration Problem Resolution in Centrifugal Pump through Design Change [PDF]

open access: yes, 2016
Case StudyCase Study 4: The case study is about single stage API BB2 pump. Pump operates at the temperature of 355 degree C (671 degree F), rated for pumping 442 m3/hr of Hydro-treated VGO (Vacuum Gas Oil) and is driven by a steam turbine.
Singh, Navneet   +2 more
core   +1 more source

Effectiveness of Resistance Intradialytic Exercise Compared to Aerobic Intradialytic Exercise for Patients With Chronic Kidney Disease: A Randomized Controlled Clinical Trial

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Patients with chronic kidney disease undergoing hemodialysis commonly experience reduced physical function, fatigue, poor sleep quality, and impaired health‐related quality of life. Intradialytic exercise has been proposed as a non‐pharmacological strategy to improve these outcomes.
Klebson da Silva Almeida   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy