Results 71 to 80 of about 644 (184)

Simulation and Characterization of Micro-Discharge Phenomena Induced by Glitch Micro-Defects on an Insulated Pull Rod Surface

open access: yesEnergies
The reliability of GIS (gas-insulated switchgear) circuit breakers significantly depends on the condition of the insulated pull rods, with micro-defects on their surface posing a potential risk for micro-discharges and breakdown incidents. Experimentally
Shu Niu   +8 more
doaj   +1 more source

Study on surface flashover characteristics of basin-type insulators under low-frequency transmission based on multiphysics coupling

open access: yesZhejiang dianli
To study the surface flashover characteristics of single-phase basin-type insulators in gas insulated metal-enclosed switchgear (GIS) under low-frequency transmission, an electro-thermal-fluid coupling simulation is employed.
LI Guoqiang   +6 more
doaj   +1 more source

3D Printing Technique-Improved Phase-Sensitive OTDR for Breakdown Discharge Detection of Gas-Insulated Switchgear. [PDF]

open access: yesSensors (Basel), 2020
Chen Z   +9 more
europepmc   +1 more source

Investigating the characteristics of internal discharge shock waves in gas‐insulated switchgear under varied gap configurations

open access: yesIET Generation, Transmission & Distribution
Gas‐insulated switchgears (GIS) are crucial components of high‐voltage power transmission and distribution systems. Internal discharges within GIS have garnered significant attention in the field of power engineering.
Chenglong Jia   +3 more
doaj   +1 more source

Method for Sensing the Temperature Rise Rate of GIS Busbar Conductors Considering Transient Ambient Temperature

open access: yesIET Science, Measurement & Technology
Currently, the perception of temperature rise inside the gas insulated switchgear (GIS) is mainly achieved by fitting and training steady‐state temperature values, whereas abnormal temperature rise is a long and slow transient process, so there is a lack
Hangyu Cao   +5 more
doaj   +1 more source

Shape optimisation of basin insulator for DC gas insulated switchgear/gas insulated transmission lines based on artificial bee colony algorithm

open access: yesHigh Voltage
The surface charge accumulation on the basin insulator is a particular problem in high‐voltage direct current (HVDC) gas insulated switchgears (GIS) and gas insulated transmission lines (GIL), which restricts the development and application of extra ...
Yi Luo   +4 more
doaj   +1 more source

Metal particle contamination in gas-insulated switchgears/gas-insulated transmission lines

open access: yesCSEE Journal of Power and Energy Systems, 2021
Jian Wang   +7 more
openaire   +1 more source

Home - About - Disclaimer - Privacy