Results 41 to 50 of about 4,651 (229)

An Improved Fast Computational Method for Vibration Characteristic Analysis of Dry‐Type Iron Core Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT Structural mechanics field simulation plays a critical role in the vibration characteristic analysis of electrical equipment. Existing structural field analysis of equipment based on numerical simulation faces challenges such as convergence difficulties and prolonged computational time, failing to meet the demand for real‐time prediction of ...
Wanqing Wang   +6 more
wiley   +1 more source

The extraction method of evaluation index of safety insulation status of GIS equipment operation based on simplified indicators

open access: yesDiance yu yibiao
Extracting the characteristic indicators of SF6 gas insulated switchgear that reflects equipment insulation status to evaluate its insulation state is the basis for safe operation.
GAO Yibo   +3 more
doaj   +1 more source

Development of ± 550 kV DC GIS Basin Insulator

open access: yesHigh Voltage, EarlyView.
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao   +9 more
wiley   +1 more source

Investigation of Gas-Sensing Property of Acid-Deposited Polyaniline Thin-Film Sensors for Detecting H2S and SO2

open access: yesSensors, 2016
Latent insulation defects introduced in manufacturing process of gas-insulated switchgears can lead to partial discharge during long-time operation, even to insulation fault if partial discharge develops further.
Xingchen Dong   +4 more
doaj   +1 more source

Anomaly Detection for Partial Discharge in Gas-Insulated Switchgears Using Autoencoder

open access: yesIEEE Access, 2020
In this article, we propose a new anomaly detection method to detect the partial discharge in a gas-insulated switchgear. An autoencoder was used for anomaly detection and was modeled on the one-class classification problem.
Ngoc-Diem Tran Thi   +4 more
doaj   +1 more source

The suitability of N2 to replace SF6 in a triggered spark-gap switch for pulsed power applications [PDF]

open access: yes, 2009
The high dielectric strength of sulphur hexafluoride (SF6) when compared with other gases, coupled with safety benefits such as non-flammability and non-toxicity, has seen the widespread use of SF6 for the insulation of switching components. However, SF6
Given, M.J.   +6 more
core  

Highly Selective Adsorption of Fluorinated Gases by Porous Organic Cages – Effects of Fluorinated Side‐Chains

open access: yesAdvanced Materials, Volume 38, Issue 7, 2 February 2026.
A systematic study of a series of porous organic cages with perfluorinated alkyl side‐chains of different lengths is presented. The structure‐property relationship of the various cages on gas sorption of highly potent greenhouse gases, such as perfluorocarbons (PFCs), sulfur hexafluoride (SF6), and nitrogen trifluoride (NF3) is investigated.
Ke Tian   +8 more
wiley   +1 more source

Adsorption properties of Ni cluster modified TiO2 (1 0 1) towards SF6 decomposition gases

open access: yesHigh Voltage, 2023
Online detection of insulation defects the decomposition products of SF6 plays a key role in ensuring the safe operation of the gas‐insulated switchgear (GIS) equipment. The pristine TiO2 (1 0 1) modified by Ni cluster (1–3 Ni atoms) is used as a new gas‐
Yingang Gui   +3 more
doaj   +1 more source

Sifat Dielektrik Campuran Gas CO2 dengan Nitrogen (N2) Dibawah Terpaan Medan Tinggi DC Polaritas Positif [PDF]

open access: yes, 2017
Sulfur hexafluoride gas (SF6) is widely used in the power electrical system such as circuit breaker, gas insulated switchgear (GIS) and gas insulated line (GIL).
Anderson, M. (Michael)   +1 more
core  

Spectral Characteristics and Evolution Mechanism of Silicon Rubber Surface Discharge Under Thermal Ageing Condition

open access: yesHigh Voltage, Volume 11, Issue 1, Page 192-200, February 2026.
ABSTRACT Surface discharge is a typical fault type in electric power equipment. High temperature in long‐term operation can easily lead to ageing of materials, resulting in changes in surface characteristics and surface discharge faults. In this paper, a method of surface discharge identification of silicon rubber (SiR) based on spectral detection ...
Yanze Han   +6 more
wiley   +1 more source