Results 191 to 200 of about 45,779 (252)

Targeting Post‐Irradiation Thyroid Dysfunction: Electrospun Scaffolds As A Dual‐Action Approach for Antioxidant and Immune Modulation

open access: yesAdvanced Healthcare Materials, EarlyView.
Radiation‐induced hypothyroidism follows head and neck radiotherapy due to oxidative stress and inflammation. Electrospun polycaprolactone scaffolds containing adenosine have potential to modulate thyroid repair. Scaffolds enhance thyrocyte proliferation, antioxidant enzymes glutathione peroxidase and catalase, reduce senescence and apoptosis markers ...
Maria Heim   +5 more
wiley   +1 more source

Co‐Electrospinning Extracellular Matrix with Polycaprolactone Enables a Modular Approach to Balance Bioactivity and Mechanics of a Multifunctional Bone Wrap

open access: yesAdvanced Healthcare Materials, EarlyView.
The incorporation of nondigested ECM and synthetic polymers into a co‐electrospinning system enables the decoupling of bioactivity and mechanical properties within a single wrap. This technique is used to develop a multifunctional bone wrap that achieves augmented membrane durability, sustained infection control, and enhanced vascularity for use in ...
Sarah Jones   +14 more
wiley   +1 more source

Modular Control of PEG‐Poly(2‐Oxazoline) Co‐Assembly Enables Tunable Aggregate Properties for Intraocular Pressure Management

open access: yesAdvanced Healthcare Materials, EarlyView.
A thermo‐responsive poly(2‐oxazoline)‐based injectable formulation is developed to modulate intraocular pressure (IOP) in both normal and hypotonic eyes. By adjusting the PEG content, the aggregation behavior is finely tuned, enabling IOP elevation without long‐term deposition.
Yuji Tanaka   +2 more
wiley   +1 more source

Flash Assembloids: A Rapid Biofabrication of a Platform for Modeling Early Glioblastoma Invasion at the Glioblastoma–Brain Organoid Interfaces

open access: yesAdvanced Healthcare Materials, EarlyView.
This study presents a bioengineered assembloid (ASM) system combining glioblastoma (GBM) cells in oxidized alginate (OA) microgels with dorsal organoids (DOs). This model simulates brain tumor‐host interactions, revealing enhanced GBM invasion, altered gene expression, and aggressive infiltration patterns, demonstrating ASM as a valuable platform for ...
Chao Liang   +17 more
wiley   +1 more source

Photothermal‐Activated Antibacterial Amyloid‐Polyphenol‐Iron Hydrogels for Synergistic Wound Healing

open access: yesAdvanced Healthcare Materials, EarlyView.
We report a thermally triggered supramolecular hydrogel (LTFe) formed by Fe3+ and tannic acid on lysozyme amyloid fibrils. Fe3+ enables rapid gelation and photothermal transduction with an efficiency of 88.56%. The LTFe hydrogel exhibits excellent biocompatibility, potent antibacterial activity against E. coli and S.
Di Wu   +8 more
wiley   +1 more source

Hydrogel Microtube Drug Carrier for Catheter‐Based Intravascular Therapy

open access: yesAdvanced Healthcare Materials, EarlyView.
This paper proposes hydrogel microtube carriers composed of barium alginate gel, enabling long‐term vascular retention without interrupting blood flow. Intravascular treatments have long been attracting attention for therapeutic efficacy, yet practical delivery methods remained unestablished.
Shota Sato   +8 more
wiley   +1 more source

Atomic Layer Deposition Processes: Versatile Platforms for Engineering ZnO‐Chitosan Biointerfaces

open access: yesAdvanced Healthcare Materials, EarlyView.
Vapour phase metalation (VPM), multiplied pulsed vapour phase infiltration (MPI), and O2 plasma‑enhanced atomic layer deposition (PEALD) tailor Zn–chitosan (Zn‑CS) films. PEALD improves wettability and biocompatibility. MPI enhances semiconductor behavior. Antiseptic selectivity: VPM → E. coli; MPI → H. pylori.
Mabel Moreno   +17 more
wiley   +1 more source

Immunoinflammatory Mechanisms and Biocompatibility of Bioactive Dental Biomaterials: From Fundamental Insights to Clinical Translation

open access: yesAdvanced Healthcare Materials, EarlyView.
Surface‐host dialogue at the implant interface governs biological fate and osseointegration. Surface physicochemical properties of titanium (Ti) dental implants, including microgrooves, nanopatterns, nanotopography, roughness, and wettability, modulate the initial adsorption of proteins and the formation of a dynamic biointerface.
Daniela Moreira Cunha   +9 more
wiley   +1 more source

General Anesthetic Techniques

International Anesthesiology Clinics, 1994
General anesthesia is the most common form of anesthetic management for ambulatory surgery. Patients, in general, prefer general anesthesia because it is less anxiety provoking. During the last decade, the availability of several short-acting agents with high clearance has made general anesthetic techniques much safer and more predictable for ...
S K, Pandit, C R, Green
openaire   +2 more sources

Anaphylaxis to General Anesthetics

2010
The incidence of hypersensitivity reactions to anesthetics is estimated 1 in 13,000 anesthetics up to 1 in 3,180. The rate of mortality ranges between 3 and 9%. 90% of reactions appear at anesthesia induction. Cardiovascular collapse and bronchospasm are more frequent in IgE-dependent reactions.
Anne, Moneret-Vautrin, P Michel, Mertes
openaire   +2 more sources

Home - About - Disclaimer - Privacy