Results 21 to 30 of about 27,445 (197)
Evaluation of discomfort of Goldmann tonometry without anaesthetic
Goldmann applanation tonometry (GAT) is considered the gold standard technique for tonometry. It is a procedure involving administration of topical anaesthetic (a drug which could have several side effects).
António Manuel Gonçalves Baptista +9 more
core +4 more sources
Goldmann tonometry tear film error and partial correction with a shaped applanation surface. [PDF]
Purpose: The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. Methods: The separation force of a tonometer prism adhered
McCafferty SJ +3 more
europepmc +3 more sources
Evaluation of agreement of IOP measurements by Tono-Vera tonometer to Goldmann applanation tonometry [PDF]
PurposeTo evaluate the accuracy of the new Tono-Vera rebound tonometer (Reichert Inc, Buffalo, NY) compared to Goldmann Applanation Tonometry.MethodsThis prospective, observational, cross-sectional study was designed in accordance with ANSI Z80.10-2014 ...
Charles R. Niles +3 more
doaj +2 more sources
G Mangouritsas, S Mourtzoukos, A Mantzounis, L AlexopoulosGlaucoma Department, Eye Clinic, “Hellenic Red Cross” General Hospital, Athens, GreeceObjective: To compare measurements obtained by Goldmann applanation tonometry (GAT) and ...
Mantzounis A +3 more
doaj +1 more source
A Comparative Analysis of Goldmann Tonometry Correction [PDF]
Purpose: The measurement of intraocular pressure (IOP) by Goldmann applanation tonometry (GAT) is based on assumptions about corneal parameters. To correct for variations in corneal curvature and thickness, a number of equations have been proposed.
Asjeczyk-Widlicka, Magdalena +2 more
openaire +2 more sources
Comparison of Goldmann applanation tonometry and Icare tonometry
AbstractPurposeTo compare the variation of intraocular pressure (IOP) measured with Goldmann applanation tonometry (GAT) and Icare tonometry, and further determine if the two methods were calibrated to each other.MethodsTotally 20 subjects within normal IOP range were evenly divided into two method groups.
Zhaohua Yu +3 more
openaire +1 more source
Comparison Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry [PDF]
To compare the intraocular pressures (IOPs) measured by dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT), and to investigate the association of IOPs on eyes of varying central corneal thickness (CCT).In this prospective study, 451 eyes of 233 subjects were enrolled. IOPs were measured by GAT and DCT. CCT was measured three times
Lee, Jooeun +6 more
openaire +2 more sources
Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients [PDF]
Background: To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients.
Vincent, Roslyn +10 more
core +1 more source
Background The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this
Grus Franz-H +2 more
doaj +1 more source