Results 41 to 50 of about 27,445 (197)

Variation in measuring and ophthalmic factors correlating with central corneal thickness in the Northern Finland birth cohort eye study

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose To assess the correlation between optical coherence tomography (OCT) and ultrasound pachymetry (USP) as methods for analysing central corneal thickness (CCT) and to evaluate ophthalmic factors affecting CCT. Methods The eyes of 3070 subjects of the Northern Finland Birth Cohort (NFBC) were examined at the age of 45–49 years.
Tuomas Qvist   +3 more
wiley   +1 more source

Longitudinal changes in bleb morphology following the PAUL Glaucoma Implant visualized using ultrasonography

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose To evaluate bleb morphology longitudinally using sonography following glaucoma drainage device (GDD) surgery. Methods Prospective observational cohort study conducted from January 2022 to March 2024, with follow‐up up to 12 months postoperatively. Bleb morphology, including superior and inferior bleb height, transverse and longitudinal
Constance Liegl   +9 more
wiley   +1 more source

Pressure Phosphene Self-Tonometry: A Comparison with Goldmann Tonometry in Glaucoma Patients

open access: yesInvestigative Opthalmology & Visual Science, 2004
To evaluate whether the pressure phosphene tonometer (PPT) is suitable for self-tonometry in patients with glaucoma or ocular hypertension.This was a prospective comparative study of 102 eyes of 102 patients with chronic glaucoma or ocular hypertension.
Lam, D.S.C.   +7 more
openaire   +4 more sources

Evaluation of the agreement and reliability of Transpalpebral Tonometers compared with Goldmann Applanation Tonometer – A systematic Review and Meta-Analysis Protocol

open access: yesIndian Journal of Ophthalmology, 2023
In 2020, the global prevalence of glaucoma was estimated to be 76 million and it was projected to increase to 111.8 million by 2040. Accurate intraocular pressure (IOP) measurement is imperative in glaucoma management since it is the only modifiable risk
Selvaraj Jerrome   +7 more
doaj   +1 more source

Clinical outcomes of the PAUL® glaucoma implant for secondary glaucoma

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose Secondary glaucoma encompasses a broad spectrum of disease entities arising from diverse ocular pathologies and is often refractory to conventional treatment. Glaucoma drainage devices (GDDs) have therefore become an important surgical option.
Carolin Deubel   +7 more
wiley   +1 more source

Avaliação das técnicas de antissepsia bacteriana do cone de aplanação dos tonômetros de goldmann em uso em consultórios e Hospitais da grande Florianópolis. [PDF]

open access: yes, 2006
Trabalho de Conclusão de Curso - Universidade Federal de Santa Catarina. Curso de Medicina.
Daguano, Carolina Rottili
core  

Corneal hydration and the accuracy of Goldmann tonometry. [PDF]

open access: yes, 2006
The purpose of this thesis was to investigate the effect of corneal swelling on the accuracy of Goldmann tonometry estimates of intraocular pressure (IOP).
Hamilton, Kirsten
core   +1 more source

Comparison of IOPen rebound tonometer with Goldmann applanation tonometer at different IOP levels [PDF]

open access: yesInternational Journal of Ophthalmology, 2013
AIM:To compare the accuracy of IOPen rebound tonometer with Goldmann applanation tonometer (GAT) in individuals with low, normal and high intraocular pressure (IOP) and to evaluate the effect of central corneal thickness (CCT) on IOP measurements.METHODS:
FereydounFarrahi   +3 more
doaj   +1 more source

Neovascular glaucoma at a tertiary Centre in Finland, 2008–2024: A retrospective cohort study

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose Neovascular glaucoma (NVG) is a refractory secondary glaucoma, yet longitudinal outcome data remain limited. This study reports its aetiologies, treatments and outcomes. Methods Patients with NVG were identified through electronic medical record review.
Gilbert Simons   +3 more
wiley   +1 more source

Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry

open access: yesJournal of the Korean Ophthalmological Society, 2009
Purpose: To compare dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) and investigate the influence of central corneal thickness (CCT) onintraocular pressure. Methods: In a prospective study of 165 eyes with glaucoma (135 eyes), glaucoma suspect (14 eyes), and ocular hypertension (16 eyes), intraocularpressure was measured with ...
Jang Won Seo   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy