Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations
In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam.
Maddalena De Bernardo +5 more
doaj +1 more source
Accuracy of Schiotz Tonometry in Measuring the Intraocular Pressure After Corneal Refractive Surgery
Purpose: To test the accuracy of Schiotz tonometry (ST) in patients that underwent photorefractive keratectomy (PRK). Methods: 175 eyes previously treated with PRK for myopia, myopic astigmatism or mixed astigmatism, with a mean preoperative spherical ...
Nicola Rosa +7 more
doaj +1 more source
Background and objectives: Intraocular pressure plays a crucial role in maintaining vision and preventing eye disease. Beyond its importance in diagnosing and managing glaucoma, intraocular pressure measurements significantly impact the evaluation of ...
Yaseen Ahmed Ali, Tara Mahmood Hassan
doaj +1 more source
Reutilization of disposable rebound tonometer probes: Risk or return?
Purpose: An advantage of rebound tonometry (RT) is its ease of use so that it can also be operated by health care technicians. However, the cost of the disposable measuring probes is high and their reuse carries the risk of infection.
Christian Enders +4 more
doaj +1 more source
Goldmann applanation tonometry versus non-contact tonometry: a comparative study [PDF]
Background: Intraocular pressure (IOP) measurement is a routine procedure in complete ophthalmologic examination and finds importance in diagnosis and monitoring of glaucoma.
Chakrabarty, Lipi
core +1 more source
Introduction: The purpose of this study was to compare iCare HOME (TA022) with Goldmann applanation tonometer and to evaluate the self-tonometry measurements among the Indian population.
Aditya Chaitanya +4 more
doaj +1 more source
Objective: To compare intraocular pressure measurements by iCare 200 and Goldmann applanation tonometer in patients having central corneal thickness within normal limits. Study Design: Cross-sectional study.
Taimoor Ashraf Khan +5 more
doaj +1 more source
PurposeTo compare intraocular pressure (IOP) values obtained using Goldmann applanation tonometry (IOPGAT) and non-contact tonometry (IOPNCT) in a non-pathologic high myopia population.MethodsA total of 720 eyes from 720 Chinese adults with non ...
Peiyuan Wang +10 more
doaj +1 more source
Abstract Purpose To evaluate real‐world safety experience with aflibercept 8 mg in a large case series of patients with neovascular age‐related macular degeneration (nAMD). Methods Due to a high proportion of patients on short treatment intervals, patients with nAMD at a Danish tertiary retina clinic were systematically switched to aflibercept 8 mg ...
Mary Graciya Karunainathan +12 more
wiley +1 more source
Background: Repeatability and validity are important components of precision in any measurement system. Aim: This study aimed to determine the effect of change in head and neck position and body posture on the repeatability of intraocular pressure (IOP)
Ahmed I. Tairi +6 more
doaj +1 more source