Results 61 to 70 of about 7,561 (175)
Comparison of Rebound and Applanation Tonometry in Eyes With Focal Corneal Edema
ABSTRACT Objective To determine the effect of corneal edema on intraocular pressure (IOP) readings and their accuracy and precision when obtained with handheld rebound and applanation tonometers. Animals and Procedures IOP readings from areas of focal corneal edema were compared to those from clear cornea in 10 eyes of 7 glaucomatous cats in vivo using
Julie A. Kiland +7 more
wiley +1 more source
Pressure-Induced Stromal Keratopathy after Surface Ablation Surgery
Introduction: The purpose of this clinical report was to describe an unprecedented case of bilateral pressure-induced stromal keratopathy (PISK) following corneal photorefractive keratectomy, associated with presumed herpetic keratitis, and to present ...
Jaime Guedes +7 more
doaj +1 more source
INTRODUCTION[|]The aim of the present study was to compare intraocular pressure (IOP) level as measured with Goldmann applanation tonometry (GAT) and Icare rebound tonometry (RBT; Icare Finland Oy, Vantaa, Finland) in patients with varied central corneal
Isil Pasaoglu +7 more
doaj +1 more source
The incidence of serious complications after selective laser trabeculoplasty
Abstract Purpose To evaluate the incidence of serious complications after selective laser trabeculoplasty (SLT). Methods All patients who underwent SLT at the Department of Ophthalmology, Helsinki University Hospital, were eligible for the study from 1 January 2012 to 31 December 2018.
Eeva S. Ojanen +2 more
wiley +1 more source
A Mathematical Model of the Goldmann Applanation Tonometry
Abstract The aim of this study is to present mathematical formulas describing all forces involved in Goldmann applanation tonometry to calculate the measurement error of the true intraocular pressure as a function of the surface tension of the tear film, the corneal modulus of elasticity, the corneal thickness and the average apical corneal ...
Gaetano Barbaro, Ciro Caruso
openaire +1 more source
Acta Ophthalmologica, Volume 104, Issue 3, Page e356-e359, May 2026.
Michael Hafner +6 more
wiley +1 more source
Rebound Tonometry in Cataract Surgery: Comparison with Goldmann Applanation Tonometry
Purpose: to compare the rebound tonometer ICare® (RT) with the Goldmann applanation tonometer (GAT) in cataract surgery and to assess the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements. Design: retrospective, comparative study.
Chiara De Giacinto +5 more
openaire +3 more sources
Assessing the need and benefits of home tonometers in the management of patients with glaucoma
Pinakin Gunvant Davey,1 Kiana Nouri,2 Samantha Zaczyk1 1Western University of Health Sciences, College of Optometry, Pomona, CA, USA; 2Western University of Health Sciences, College of Osteopathic Medicine of the Pacific, Pomona CA, USA Abstract ...
Davey PG, Nouri K, Zaczyk S
doaj
Modalities of Tonometry and their Accuracy with Respect to Corneal Thickness and Irregularities
Recent advances in tonometry have led to the development of a number of devices with differing clinical applications. Their role in cases of abnormal corneal thickness and surface irregularities is particularly important, as inaccurate estimation of the ...
Carlos Gustavo V. De Moraes +3 more
doaj +1 more source
Anne Herr,1 Andreas Remky,2 Thalia Hirsch,1 Corinna Rennings,1 Niklas Plange1 1Department of Ophthalmology, RWTH Aachen University, Aachen, Germany; 2Augenbelegabteilung Krankenhaus Barmherzige Brueder, Regensburg, Germany Introduction: Intraocular ...
Herr A +4 more
doaj