Different methods for measuring intraocular pressure [PDF]

open access: yesHalo 194, 2019
Tonometry is a method for measuring intraocular pressure (IOP). Goldmann applanation tonometry (GAT) represents a golden standard for measuring IOP. The measurement is conducted by measuring the force needed to straighten out a certain area of the cornea.
Jordanova Elena   +6 more
doaj  

Agreement between ganglion cell‐inner plexiform layer metrics from widefield optical coherence tomography and Goldmann II, III, and V in glaucoma

open access: yesOptometry and Vision Science, Volume 103, Issue 7, July 2026.
ABSTRACT Purpose To compare concordance between ganglion cell‐inner plexiform layer metrics acquired using widefield optical coherence tomography (OCT) and visual function assessed using Goldmann (G) II, III, and V stimulus sizes, in turn evaluating the role of spatial summation properties in binary classification of visual field (VF) results.
Janelle Tong   +7 more
wiley   +1 more source

Global scope of glaucoma clinical practice for optometrists

open access: yesOptometry and Vision Science, Volume 103, Issue 7, July 2026.
ABSTRACT Purpose The role of optometrists in glaucoma care is evolving rapidly in many parts of the world. This review aims to describe the current global scope of clinical practice for optometrists with respect to glaucoma, highlighting progress and identifying barriers to care across diverse regions.
Jonathan Denniss   +9 more
wiley   +1 more source

Ciliary muscle thickness and intraocular pressure before and after latanoprost

open access: yesOptometry and Vision Science, Volume 103, Issue 6, June 2026.
ABSTRACT Purpose To test the hypothesis that a larger, latanoprost‐induced intraocular pressure (IOP) reduction is associated with a thicker ciliary muscle. Methods Participants (N = 31) were healthy with the following details: mean ± SD age 24.8 ± 3.3 years.
Emily Slywka   +2 more
wiley   +1 more source

The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature. [PDF]

open access: yesPLoS ONE, 2015
The purpose of the study was to investigate the correlation between Corneal Visualization Scheimpflug Technology (Corvis ST tonometry: CST) parameters and various other ocular parameters, including intraocular pressure (IOP) with Goldmann applanation ...
Ryo Asaoka   +8 more
doaj   +1 more source

Axial length, myopia progression, and myopic maculopathy in Stickler syndrome

open access: yesActa Ophthalmologica, Volume 104, Issue 4, Page 423-430, June 2026.
Abstract Purpose We lack knowledge on the potentially progressive nature of and the prevalence of complications to myopia as a characteristic trait of Stickler syndrome. Methods This cross‐sectional study combines ophthalmic examination and medical record data on Danish patients with genetically confirmed Stickler syndrome type 1 (COL2A1) and type 2 ...
Kirstine B. Boysen   +4 more
wiley   +1 more source

Comparative evaluation of intraocular pressure with an air-puff tonometer versus a Goldmann applanation tonometer

open access: yesClinical Ophthalmology, 2012
Qasim K FarhoodDepartment of Ophthalmology, College of Medicine, University of Babylon, Babylon, IraqPurpose: Tonometry, or measurement of intraocular pressure (IOP), is one of the most important examination procedures in ophthalmic clinics, and IOP is ...
Farhood QK
doaj  

Microelectromechanical system‐based devices for the diagnosis, treatment, and monitoring of ophthalmic diseases

open access: yesInterdisciplinary Medicine, Volume 4, Issue 3, May 2026.
Due to the characteristics of miniaturization, high sensing performance, integration, and high comfort, MEMS‐based devices were employed to design sensors, imaging systems, drug delivery systems, retinal prosthesis, surgical tools, and wearable products for the ophthalmic disease diagnosis, treatment, and monitoring.
Yaling Peng   +10 more
wiley   +1 more source

Comparison of three methodologies for measuring intraocular pressure in healthy cats [PDF]

open access: yesVeterinary World
Background and Aim: Measuring intraocular pressure (IOP) is crucial for identifying potentially damaging changes in the eyes, including diseases as glaucoma and uveitis.
Claudia Lizandra Ricci   +6 more
doaj   +1 more source

Incidence, risk factors, and outcomes of numerical hypotony and choroidal effusion following PRESERFLO MicroShunt implantation

open access: yesActa Ophthalmologica, Volume 104, Issue 3, Page e239-e250, May 2026.
Abstract Purpose To evaluate the incidence, outcomes, and risk factors of numerical hypotony (NH) and choroidal effusion (CE) following standalone PRESERFLO MicroShunt (PMS) implantation. Methods Primary open‐angle glaucoma (POAG) and pseudoexfoliative glaucoma (PXG) patients with uni‐ or bilateral surgery at a tertiary university hospital were ...
Emil Nasyrov   +5 more
wiley   +1 more source