Results 71 to 80 of about 7,561 (175)
Goldmann and modified Goldmann tonometry measuring intraocular pressure changes in eyes which underwent myopic laser in situ Keratomileusis and photorefractive keratectomy. [PDF]
Ang RET +3 more
europepmc +1 more source
Introduction & Objective: The measurement of Intraocular pressure (IOP) is very important not only in the diagnosis and management of glaucomatous conditions but also in any ophthalmologic examination. So this study was designed to compare the results of
Rana Sorkhabi, Pejman Khatibian
doaj
[Comparison of dynamic contour tonometry (Pascal) with pneumotonometry and Goldmann tonometry].
To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer.This was an observational clinical study, which included two hundred and five randomly selected subjects recruited from the Ophthalmology Department. The intraocular pressure measurements were performed with each tonometry
Moreno-Montañes, J. (Javier) +3 more
openaire +2 more sources
Comparison of Applanation Tonometry with and without Fluorescein
Background: Tonometry is one of the important parts of ocular examination. It has been estimated that more than 900000 people in the United State have visual problems due to glaucoma; however most of them are not aware of their disease.
Shahram Bamdad +4 more
doaj
Gabi Shemesh,* Uri Soiberman,* Shimon KurtzDepartment of Ophthalmology, Tel Aviv Medical Center, and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel*These two authors contributed equally to this workBackground and methods: Myopic ...
Shemesh G, Soiberman U, Kurtz S
doaj
Nisa Silva,1 André Ferreira,1,2 Pedro Manuel Baptista,1 Ana Figueiredo,1 Rita Reis,1 Isabel Sampaio,1 João Beirão,1,3 Riccardo Vinciguerra,4,5 Pedro Menéres,1,3 Maria João Menéres1,3 1Ophthalmology Department, Centro Hospitalar Universitário do Porto ...
Silva N +9 more
doaj
Konstantinos Andreanos, Chryssanthi Koutsandrea, Dimitris Papaconstantinou, Andreas Diagourtas, Andreas Kotoulas, Panagiotis Dimitrakas, Marilita M Moschos First Department of Ophthalmology, University of Athens, “G.
Andreanos K +6 more
doaj
ProTon tonometer determination of intraocular pressure in patients with scarred corneas
Purpose: To evaluate the measure of intraocular pressure (IOP) in patients with scarred corneas obtained from the affected and non-affected areas.
Jain Arun, Sukhija Jaspreet, Gupta Amod
doaj
Goldmann tonometry tear film error and partial correction with a shaped applanation surface. [PDF]
McCafferty SJ +3 more
europepmc +1 more source
Correlation of Central Corneal Thickness with Schiotz and Goldmann Tonometry
<!--[if gte mso 9]><xml> Normal 0 false false false MicrosoftInternetExplorer4 </xml><![endif]--><!--[if gte mso 9]><xml> </xml><![endif]--> <!--[if gte mso 10]> <style> /* Style ...
Mohammad-Reza Razeghinejad +3 more
doaj