Results 81 to 90 of about 27,445 (197)

Measurement of Intraocular Pressure with Goldmann Applanation Tonometry, Dynamic-Contour Tonometry, and Ocular Response Analyzer

open access: yes, 2016
Intraocular pressure (IOP) is an eye parameter of fundamental importance for the diagnosis of several eye conditions. The clinical standard for IOP measurement is Goldmann applanation tonometry (GAT), which has been the basis for the studies that ...
M. Digiuni   +5 more
core   +1 more source

Topiramate‐induced acute angle closure with suprachoroidal effusion: Insights from a novel ultra‐wide‐field OCT device

open access: yes
Acta Ophthalmologica, Volume 104, Issue 3, Page e356-e359, May 2026.
Michael Hafner   +6 more
wiley   +1 more source

Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry

open access: yesClinical Ophthalmology, 2013
Anne Herr,1 Andreas Remky,2 Thalia Hirsch,1 Corinna Rennings,1 Niklas Plange1 1Department of Ophthalmology, RWTH Aachen University, Aachen, Germany; 2Augenbelegabteilung Krankenhaus Barmherzige Brueder, Regensburg, Germany Introduction: Intraocular ...
Herr A   +4 more
doaj  

Modalities of Tonometry and their Accuracy with Respect to Corneal Thickness and Irregularities

open access: yesJournal of Optometry, 2008
Recent advances in tonometry have led to the development of a number of devices with differing clinical applications. Their role in cases of abnormal corneal thickness and surface irregularities is particularly important, as inaccurate estimation of the ...
Carlos Gustavo V. De Moraes   +3 more
doaj   +1 more source

Applanation pressure function in Goldmann tonometry and its correction [PDF]

open access: yes, 2013
So far applanation tonometry has not worked out any theoretical basis for correcting the result of intraocular pressure measurement carried out on a cornea with noncalibration dimensions by means of the Goldmann tonometer.
Śródka, W.
core  

Bland-Altmann Plot for agreement between Goldmann applanation tonometry (GAT) and corneal-compensated IOP (IOPcc).

open access: yes, 2017
Bland-Altmann Plot for agreement between Goldmann applanation tonometry (GAT) and corneal-compensated IOP (IOPcc).
Norbert Pfeiffer (26543)   +6 more
core   +1 more source

Diurnal Variation of Central Corneal Thickness and Goldmann Applanation Tonometry Estimates of Intraocular Pressure

open access: yes, 2007
URPOSE: To determine whether there is a temporal relationship between the diurnal variation of central corneal thickness (CCT) and intraocular pressure (IOP) by Goldmann applanation tonometry in young normal human participants in vivo.
Pye, D. C.   +5 more
core   +1 more source

[Comparison of dynamic contour tonometry (Pascal) with pneumotonometry and Goldmann tonometry].

open access: yesArchivos de la Sociedad Espanola de Oftalmologia, 2007
To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer.This was an observational clinical study, which included two hundred and five randomly selected subjects recruited from the Ophthalmology Department. The intraocular pressure measurements were performed with each tonometry
Moreno-Montañes, J. (Javier)   +3 more
openaire   +2 more sources

Applanation pressure function in Goldmann tonometry and its correction

open access: yes, 2020
So far applanation tonometry has not worked out any theoretical basis for correcting the result of intraocular pressure measurement carried out on a cornea with noncalibration dimensions by means of the Goldmann tonometer.
Wiesław Śródka
core  