Results 81 to 90 of about 49,234 (298)
A carbon‐free, as‐sintered MgO–steel cermet anode, fabricated via cold isostatic pressing using MgO–C refractory recyclate, was evaluated under laboratory‐scale K‐cryolite electrolysis at 800°C. Operation at this reduced temperature, combined with the electrolyte's limited electrical conductivity, led to an increase in cell voltage.
Farhan Hossain +7 more
wiley +1 more source
This study primarily simulates the flashover phenomenon between the metal fittings (rods) and the skirt surface (plates) of insulators when water droplets traverse between them under heavy rain conditions.
Jianli Zhao +4 more
doaj +1 more source
Low‐consumable nickel ferrite‐based anodes for the Hall–Héroult process are compared with conventional prebaked carbon anodes using thermodynamic simulation and prospective life cycle assessment under contrasting future electricity system pathways from 2025 to 2050.
Felipe Alejandro Garcia Paz +6 more
wiley +1 more source
This study aims to use an artificial neural network to forecast the flashover voltage of a polluted high-voltage insulator. Practical tests were conducted on a high-voltage insulator to gather data for the neural network.
Mardini Hasanah +5 more
doaj +1 more source
Time domain analysis of switching transient fields in high voltage substations [PDF]
Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within ...
Judd, M.D., Musa, B.U., Siew, W.H.
core
Interaction of Ladle Slag With Varying SiO2 Content and Recyclate‐Based MgO–C Refractories
Ladle slags (CaO/Al2O3 = 1) with 1–20 wt% SiO2 were investigated in contact with industrial MgO–C refractories fabricated from fresh magnesia and 50 wt% recyclate. The sessile drop method at 1600°C reveals intensive gas formation, delayed slag infiltration in recyclate‐based samples, and, under high‐SiO2 slag, formation of a dense MgAl2O4‐rich ...
Anton Yehorov +6 more
wiley +1 more source
Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC [PDF]
In Malaysia, the demand for electric power is increasing day by day due to more consumption of power in the industrial sector. Recently, the high voltage DC transmission lines are under construction near the coastal environments for transmitting the ...
Ahmad, H. +6 more
core
Photocurrent measurements in topological insulator $\text{Bi}_2\text{Se}_3$ nanowires
Circular photogalvanic currents are a promising new approach for spin-optoelectronics. To date, such currents have only been induced in topological insulator flakes or extended films. It is not clear whether they can be generated in nanodevices.
Geishendorf, K. +4 more
core +1 more source
This paper presents a novel approach to reducing oxide layers on metal powders using low‐temperature hydrogen dielectric barrier discharge plasmas at atmospheric pressure. Unlike conventional hydrogen‐plasma reductions, the powders do not contact the plasma directly.
Shukang Zhang +3 more
wiley +1 more source
Structural health monitoring of high voltage electrical switch ceramic insulators in seismic areas [PDF]
High voltage electrical switches are crucial components to restart rapidly the electrical network right after an earthquake. But there currently exists no automatic procedure to check if these ceramic insulators have suffered after an earthquake, and ...
BARTHES, Clément +3 more
core +3 more sources

