Results 21 to 30 of about 620 (264)
In order to improve the fault monitoring performance of grounding electrode lines in ultra-high voltage DC (UHVDC) transmission systems, a novel fault monitoring approach based on the high-frequency voltage standing-wave ratio (VSWR) is proposed in this ...
Yufei Teng +6 more
doaj +1 more source
In order to enhance the security of ±800 kV High-Voltage DC (HVDC) system, it is needed to consider and analyze the grounding mode of the neutral point of converter transformer.
Jiaqing Fu +4 more
doaj +1 more source
Sheath currents in high voltage cable circuits have proven to be one of the most convenient indicators for assessing cable health. The sheath currents are regularly distributed with fluctuation in a certain range under normal conditions, while the ...
Gen Li +5 more
doaj +1 more source
Multiple voltage drops or abnormal currents may occur in the power system, resulting in significant deformation and fluctuation of fault signal characteristics related to the medium voltage DC distribution network, exceeding the normal fluctuation range,
Peng ZHENG +3 more
doaj +1 more source
In view of problems of complex fault situation and unobvious characteristics of fault signal of fault line selection method of existing small current grounding system, a fault line selection method of small current grounding system based on wavelet ...
WANG Xiaowei +3 more
doaj +1 more source
To address challenges in locating high-impedance grounding faults (HIGFs) and isolating fault areas in resonant grounding systems, this paper proposes a novel fault identification method based on coordinating a Peterson coil and a resistance grounding ...
Zhengyang Li +4 more
doaj +1 more source
Characteristics of the Flexible Graphite Grounding Material and its Engineering Application
In order to meet the requirements of corrosion resistance of the grounding material and thermal stability of the grounding material of the transmission line towers, under the condition of power frequency current and high-frequency lightning current ...
Daochun Huang +4 more
doaj +1 more source
Principle of Flexible Ground-Fault Arc Suppression Device Based on Zero-Sequence Voltage Regulation
Single-line-to-ground (SLG) fault arcs cause the intermittent over-voltages, leading to short circuits within large-scale area. In this paper, a flexible arc suppression device is proposed, which adopts a zigzag grounding transformer, multi-terminal ...
Bishuang Fan +6 more
doaj +1 more source
ABSTRACT Objective Glioma recurrence severely impacts patient prognosis, with current treatments showing limited efficacy. Traditional methods struggle to analyze recurrence mechanisms due to challenges in assessing tumor heterogeneity, spatial dynamics, and gene networks.
Lei Qiu +10 more
wiley +1 more source
To address the poor tolerance to transitional resistance and incomplete utilization of fault information in grounding protection for flexible grounding systems, a fault line selection method based on current phase variation is proposed.
LI Zong +5 more
doaj +1 more source