Results 81 to 90 of about 89,812 (215)

Monolithic 3D‐Integrated All‐Solid Ion‐Gated Carbon Nanotube Transistors With Tunable Ionic Conductance for Multi‐Timescale Reservoir Computing

open access: yesAdvanced Materials, EarlyView.
A dual‐timescale reservoir based on monolithically 3D (M3D)‐integrated CNT solid ion‐gated transistors is demonstrated. Tunable ionic dynamics and pulse‐engineered operation enable linear and symmetric synaptic updates. The M3D‐integrated array achieves robust temporal encoding and accurate classification of moving MNIST sequences, highlighting its ...
Haksoon Jung   +9 more
wiley   +1 more source

De Novo Autogenic Engineered Living Functional Materials

open access: yesAdvanced Materials, EarlyView.
A versatile platform for de novo autogenic engineered living materials is presented, leveraging protein mining, computational modeling, and synthetic biology. By reprogramming the Escherichia coli curli machinery with β‐solenoid proteins from non‐model bacteria, macroscopic biomaterials with enhanced mechanical properties, UV‐C irradiation protection ...
Hoda M. Hammad   +9 more
wiley   +1 more source

Sustainable Poly(Lactic Acid)/Graphene Oxide Bioelectronic Platform for Neurotransmitters Sensing and Tunable Stimulation of Astrocytes

open access: yesAdvanced Materials, EarlyView.
This work introduces sustainable PLA/graphene oxide bioelectronic interfaces featuring electrodes with tunable conductivity and strong electrocatalytic performance. These platforms were used to implement a new method for tuning astrocyte Ca2+ signaling and for the efficient detection of key biomarkers.
Alessandra Scidà   +15 more
wiley   +1 more source

Controlled Synthesis of Tri‐ and Multi‐Doped Graphene

open access: yesAdvanced Materials Interfaces, EarlyView.
This review systematically evaluates synthesis routes for tri‐ and multi‐doped graphene, from hydrothermal and pyrolysis methods to flash Joule heating, critically assessing how each governs dopant incorporation, bonding configuration, and resulting electronic properties.
Maria Hasan   +4 more
wiley   +1 more source

Development of a Chicken Immunoglobulin Heavy Chain Variable Region (VH) Single-Domain Antibody (sdAb) Against Calsequestrin (CSQ) and Its Application

open access: yesAntibodies
Background/Objectives: Calsequestrin (CSQ) is a calcium-binding protein that is highly soluble and can serve as a solubility-enhancing fusion tag in recombinant protein expression.
Sun Lee   +8 more
doaj   +1 more source

Chaotropic Surface Arginine Correlates With Protein Corona Formation on Anti‐Fouling Biomaterial Surfaces: A Quantitative Proteomics and Protein Structure Study

open access: yesAdvanced Materials Interfaces, EarlyView.
Why do specific proteins accumulate on “non‐fouling” surfaces? Quantitative proteomics and structural analysis reveal surface‐exposed arginine as the key molecular determinant. ABSTRACT The protein corona determines the biocompatibility of medical devices, yet predicting its composition on anti‐fouling surfaces remains challenging.
Ayano Nomura   +5 more
wiley   +1 more source

Gate‐Induced Critical Current Modulation in W–C Nanowires: The Role of Fabrication

open access: yesAdvanced Materials Technologies, EarlyView.
Focused ion beam induced deposition (FIBID) enables precise control of superconducting W–C nanowire devices. Introducing a Ga+ focused ion beam (FIB) cleaning step reduces substrate damage and suppresses leakage currents, shifting gating thresholds to higher voltages.
Alba Arroyo‐Fructuoso   +2 more
wiley   +1 more source

Artificial Synaptic Device Based on Self‐Aligned c‐In2O3 TFTs With an Ultrathin MgO Interlayer

open access: yesAdvanced Materials Technologies, EarlyView.
A coplanar synaptic thin‐film transistor based on crystalline In2O3 is demonstrated using a PECVD SiO2 gate insulator and an ultrathin MgO interlayer. The MgO interlayer suppresses excessive carrier density and may facilitate proton‐related interfacial polarization, resulting in stable counterclockwise hysteresis and synaptic behavior.
Samiran Roy, Jewel Kumer Saha, Jin Jang
wiley   +1 more source

Electroactive 3D Porous Graphene Foam Impedimetric Biosensor for Ultrasensitive Detection of MCF‐7‐Cells‐Derived Extracellular Vesicles in Human Serum

open access: yesAdvanced Materials Technologies, EarlyView.
A label‐free impedimetric biosensor based on electroactive 3D porous graphene foam enables ultrasensitive and selective detection of CD81 protein and MCF‐7 cell‐derived extracellular vesicles in human serum. Detection limits of 0.048 fg/mL for CD81 and ∼24 EVs/mL are achieved, demonstrating a robust platform for selective, label‐free, and ...
Michael Robert Furness   +11 more
wiley   +1 more source

Unveiling the Hidden Geometry of OECTs: Contact‐Semiconductor Overlap Driven Errors in Volumetric Capacitance

open access: yesAdvanced Materials Technologies, EarlyView.
This work examines how contact–semiconductor overlap influences volumetric capacitance extraction in organic electrochemical transistors as device dimensions shrink. It shows that neglecting overlap leads to systematic, geometry‐driven errors in capacitance values.
Renan Colucci   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy