Results 221 to 230 of about 196,008 (271)
Some of the next articles are maybe not open access.

Research on insulation detection of insulator strings with fuzzy logical reasoning method

Kybernetes, 2009
PurposeThe purpose of this paper is to introduce the realizing process of the fuzzy logical reasoning method in relation to the insulation detection of insulator strings, especially about the establishment of the fuzzy relation matrix.Design/methodology/approachUtilizing fuzzy logical reasoning method, the online fault diagnosis of the transmission ...
Xiaoning Xu, Yixiong Nie, Xiangang Peng
openaire   +1 more source

Impacts of corona rings on the insulation performance of composite polymer insulator strings

IEEE Transactions on Dielectrics and Electrical Insulation, 2015
Corona rings can improve the insulation performance of insulator strings because of their electric field grading property or can decrease the insulation performance due to their arc clearance reduction property. The resulting insulation performance of the string which is under the influence of those two conflicting effects depends on the corona ring ...
İlhan, Suat   +2 more
openaire   +3 more sources

Influence of attachment of insulating string on AC flashover strength of insulator

Proceedings of the Twenty-First Symposium on Electrical Insulating Materials, 2005
The relation between ac flashover voltage (ACFOV) and an attachment of nylon string on the insulator surface is studied in air by using a PMMA insulator which has a backside electrode. The measurements show that the ACFOV is decreased by the attachment of the string.
E. Ishikawa   +3 more
openaire   +1 more source

Investigation of single unit flashovers in HVDC insulator strings

IEEE Transactions on Power Delivery, 1996
In HVDC transmission lines, a special phenomenon, so-called single unit flashover, is observed under some special conditions. Only one or two insulator units repeat flashovers, not resulting in an overall flashover along the string. However, higher magnitudes of audible noise, radio and television interferences may give a serious problem.
Kouichi Ishikawa   +5 more
openaire   +1 more source

Reduction of AC flashover strength by the attachment of insulating strings on the insulator surfaces

Electrical Engineering in Japan, 1992
AbstractAC flashover voltage in air (ACFOV) decreases when nylon string is attached on the PMMA insulator surface which has a backside electrode. The decrease in ACFOV by the attachment is explained by the generation and the propagation of the negative surface leader along the string.
Yoshiaki Yamano   +3 more
openaire   +1 more source

The insulator string

Electrical Engineering, 1934
A series of tests on suspension insulators For power transmission lines is described this paper, and results are given which should be of interest to design engineers. The tests made included long-time Fatigue tests, the distribution of voltage over the insulator string, and the flashover voltage when some of the units are electrically defective.
openaire   +1 more source

Identifying faulty insulator strings by detecting insulator corona pulse current

POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151), 2002
The resolution to identify faulty insulator strings by detecting insulator corona current pulse was investigated in our laboratory. The influences of some facts on the detection resolution were also discussed, including the characteristics of insulators close to line, the resistance of faulty insulators, the locations of the faulty insulators, and the ...
null Cheng Rong Li   +4 more
openaire   +1 more source

DEVELOPMENT OF SOFTWARE FOR SELECTING INSULATORS AND INSULATOR STRINGS

Proceedings CIRED24
The role of overhead distribution lines for 10 kV, 20 kV and 35 kV in the functioning of the distribution system is fundamental. One of the parts of the overhead lines consists of insulators with equipment that have the role of separating the parts of the lines that are under voltage from those that are not and accept the weight of the conductor in all
Milica Vlaisavljević   +2 more
openaire   +1 more source

Evaluation of transmission line insulator for I-Type string insulator design

2016 IEEE International Conference on Power and Energy (PECon), 2016
Glazed glass cap and pin insulators that have been removed from the transmission line, have electrical characteristics ensuring them to be reused and reinstalled on lower voltage distribution level lines. The electrical properties determination involving insulator resistance, self-capacitance, corona inception voltage and flashover voltage were ...
H. Ahmad   +8 more
openaire   +1 more source

The sensitivity of identify faulty insulator string by detecting insulator corona current

Proceedings of 1998 International Symposium on Electrical Insulating Materials. 1998 Asian International Conference on Dielectrics and Electrical Insulation. 30th Symposium on Electrical Insulating Materials (IEEE Cat. No.98TH8286), 2002
Some basic study indicated that detecting insulator corona pulse current could be a way to inspect for the faulty insulator string in service. The basic principle of identifying the faulty insulators in the string will cause a high voltage drop across good insulators due to their low resistance, producing active corona discharges on good insulators ...
null Cheng Rong Li   +4 more
openaire   +1 more source

Home - About - Disclaimer - Privacy