Results 231 to 240 of about 196,008 (271)
Some of the next articles are maybe not open access.
Electric stress grading of insulator strings
Electrical Engineering, 1960THE component units of an insulator string do not carry equal voltages when the string is in service, because of stray capacitances from each unit of the string to line and to ground. The voltage across a particular unit in a string may be determined by placing a calibrated spark gap across that unit and noting the total string voltage required to make
openaire +1 more source
Mobile robot for inspection of porcelain insulator strings
Proceedings of the 2014 3rd International Conference on Applied Robotics for the Power Industry, 2014We transferred an insulator inspection robot from Korea Electric Power Corporation. The robot can inspect suspension insulator strings and tension insulator strings. And it can be operated at the highest voltage level of 345kV live-line. It can measure the resistance and the distribution voltage of the insulator, then judge the status of the insulator ...
null Liang Zhong +4 more
openaire +1 more source
Impact Loads on Tension Composite Multi-Strings of Insulator After a Single String Breaks
IEEE Transactions on Power Delivery, 2022The dynamic impact load after a single insulator of a tension composite multi-strings of insulator (MSI) set has failed is a key factor that should be considered in design. In this paper, an experimental method to obtain the dynamic tensile impact factor (DTIF) is established by considering a typical double-strings set, which is commonly used in ...
Bin Liu, Danyu Li, Caolan Liu, Jiajun Si
openaire +1 more source
Potential Distribution across a String of Insulators
International Journal of Electrical Engineering & Education, 1974The problem of determining the potential distribution across a string of insulators is solved by using the difference equation approach. Explicit expressions for the potentials are given in series as well as closed forms, and their variations with the parameters are displayed in the form of graphs.
openaire +1 more source
Flashover Performance of HVDC Iced Insulator Strings
IEEE Transactions on Dielectrics and Electrical Insulation, 2007Based on artificial icing test results, it was found that the DC flashover voltage of iced insulator strings was non-linear with different string lengths. An experimental formula of flashover voltage on iced insulators of different string lengths is introduced in this paper.
Peng Li +4 more
exaly +2 more sources
Temperature distribution on polluted insulator string model
1982 IEEE International Conference on Electrical Insulation, 1982The surface temperature of energized, wetted by steam fog, polluted insulator string model was measured and scanned from the instant of voltage application using an infra-red camera. Visicorder oscillographs were used to trace and record the leakage currents.
A. Nosseir +3 more
openaire +1 more source
The sixty-cycle flashover of long suspension insulator strings
Journal of the A.I.E.E., 1929This is a study of the 60-cycle flashover of strings up to voltages of 1100 kv., undertaken at the Ryan High-Voltage Laboratory, Stanford University. Investigation was made of the variations in flashover voltage for similar horizontal and vertical strings, with and without shields and tower members. An attempt has been made to correlate these flashover
openaire +1 more source
III — Designs and economics of suspension insulator strings
Electrical Engineering, 1932IN THE PAST the effectiveness of transmission line insulation has been judged almost entirely by its 60-cycle flashover characteristics. On this basis the wide changes in spacing and diameter of suspension insulator units have affected the over-all flashover values but little.
J. J. Torok, C. G. Archibald
openaire +1 more source
A new climbing robot for suspension insulator strings
2016 4th International Conference on Applied Robotics for the Power Industry (CARPI), 2016A novel robot system is presented in this paper, which is used to climb the suspension insulator strings mounted on the overhead wire. Only two motors are enough for the robot to cross an insulator with the cable driving mechanism and the stretching platform in a worm-like form. The mobility and security of the robot are analyzed.
Lijin Fang, Xinlin Xu, Xiaokun Guo
openaire +1 more source
Effect of Configuration on Contaminated Insulator String Performance
IEEE Transactions on Power Apparatus and Systems, 1972The performance of transmission line insulators under contaminated conditions is affected by many variables, one of which is the configuration of the string on the tower. Reported field experience indicates that horizontal and Vee strings perform better than vertical.
Robert Flugum, Aleksandar Karcic
openaire +1 more source