A review of artificial intelligence in brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen   +4 more
wiley   +1 more source

Evaluating the use of diagnostic CT with flattening filter free beams for palliative radiotherapy: Dosimetric impact of scanner calibration variability

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut   +2 more
wiley   +1 more source

On Hermite Interpolation

open access: yesJournal of Approximation Theory, 2000
AbstractMore general and stronger estimations of bounds for the fundamental functions of Hermite interpolation of higher order on an arbitrary system of nodes are given. Based on this result conditions for convergence of Hermite interpolation and Hermite– Fejér-type interpolation on an arbitrary system of nodes as well as Grünwald type theorems are ...
openaire   +2 more sources

Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka   +8 more
wiley   +1 more source

Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka   +6 more
wiley   +1 more source

Dose rate correction of a diode array for universal wedge field dosimetric verification

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen   +6 more
wiley   +1 more source

Monte Carlo modeling of radiation dose from radiation therapy with superficial x‐rays

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Reham Barghash   +3 more
wiley   +1 more source

Practical experience in commissioning ring applicators using ring applicator component type with bravos control software v1.2

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The Bravos v1.2 control software introduces a ring applicator component type (ACT) with channel length verification to address geometric characteristics and dosimetric discrepancies caused by source positioning inaccuracies. This study aims to commission the ring applicator and investigate the new ring ACT in Bravos 1.2.
Xiuxiu He   +4 more
wiley   +1 more source

Position‐dependent offset corrections for ring applicator reconstruction in cervical cancer brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi   +3 more
wiley   +1 more source

Evaluation of dosimetric and spatial accuracy of a virtual cone technique for radiosurgery using linac‐integrated CBCT‐based polymer gel dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab   +6 more
wiley   +1 more source