Results 141 to 150 of about 146,940 (312)

Ultrasound‐Activatable Piezoelectric Hydrogel Reprograms Mitochondrial Epigenetics for Osteoarthritis Therapy via the mTOR/GATD3A Axis

open access: yesAdvanced Science, EarlyView.
An ultrasound‐activatable piezoelectric hydrogel reprograms chondrocyte mitochondrial epigenetics via the mTOR/GATD3A axis, clearing damaged mitochondria and alleviating osteoarthritis progression in both mouse models and human cartilage explants. ABSTRACT The avascular nature of cartilage hinders drug delivery for osteoarthritis (OA) therapy.
Hui Zheng   +9 more
wiley   +1 more source

Unrestricted kinematic alignment for total knee arthroplasty: a mid- to long-term follow-up non-designer single surgeon study with survival analysis

open access: yesBone & Joint Open
Aims: Kinematic alignment (KA) offers a personalized approach by restoring each patient’s pre-arthritic joint lines. Unrestricted KA (urKA) removes alignment boundaries defined by restricted KA concept, but concerns regarding reproducibility and clinical
Francesco Mancuso   +5 more
doaj   +1 more source

knees

open access: yes, 1980
kneesI prepared a keel, c ut a couple of knees to make timbers, and I also got some plank sawed.GMS Nov 80Used IUsed IWithdrawnknee-cap boot, knee-knocked, knee knockers, knee-slideChecked by Raji Sreeni on Wed 12 Aug 2015; What looks like an 'e' has ...

core  

Strategy of Triple‐Gradient in Binary Pixels for Flexible Pressure Sensing with High Sensitivity and Wide‐Range Linearity

open access: yesAdvanced Science, EarlyView.
A flexible pressure sensor with triple‐gradient design of conductivity, modulus, and dimension in binary micro‐dome pixels is proposed. Based on precisely‐designed CNT/PDMS matrix, the device exhibits a linear sensitivity of 974.1 kPa−1 across range up to 1.8 MPa (R2 > 0.99), offering an effective strategy for potential applications in healthcare ...
Yifan Liu   +9 more
wiley   +1 more source

A Monolithic Janus Hydrogel Pressure Sensor for Wearable Motion and Physiological Monitoring

open access: yesAdvanced Science, EarlyView.
This work reports a monolithic Janus hydrogel pressure sensor featuring integrated conductive PEDOT and insulating PEGDA layers. The fabricated device achieves a rapid response time, a wide operating range, and good cyclic durability. The sensor demonstrates robust performance in tracking dynamic human joint motions, offering a scalable strategy for ...
Syed Atif Ali   +7 more
wiley   +1 more source

Knees are News

open access: yes, 2017
Knees are news this fall as fashion's fickle hemline rises to dizzy heights. The shorter skirts not only barely skim the kneecap but in casual sportswear even creep above it.
Post, Doris, Strang, Barbara
core  

Inverse Design of Pre‐Strain via a Predictive Electromechanical Model for Enhanced Strain Sensing

open access: yesAdvanced Science, EarlyView.
An analytical electromechanical model rooted in microcrack evolution mechanics is globally calibrated from only eight pre‐strain datasets, enabling prediction of the complete sensing response at untested pre‐strain values within the calibrated design space (R2 > 0.99).
Jia‐Chen Shang   +10 more
wiley   +1 more source

Do bald cypress knees control belowground nutrient cycling?

open access: yes
Bald cypress (Taxodium distichum) knees are an integral part of bottomland hardwood forest understory. While little is known about why they evolved, knees have been shown to contribute to wetland methane (CH4) fluxes and models have predicted they might ...
Ross, Skylar
core  

Perceived Time Shapes Physical Fatigue Accumulation and Its Neural Oscillatory Correlates

open access: yesAdvanced Science, EarlyView.
Can a clock change the course of physical fatigue? By covertly manipulating the clock calibration during repeated isometric contractions, we showed that perceived time shapes fatigue accumulation and frontal oscillatory dynamics. While fatigue accumulation was only reduced when the clock was slowed down, frontal oscillatory dynamics followed perceived ...
Pierre‐Marie Matta   +3 more
wiley   +1 more source

A Decoy‐Receptor‐Armed Biomimetic Nanotherapeutic With Inherent Tropism for Conserved Pathogenic Macrophages for Treating Osteoarthritis and Intervertebral Disc Degeneration

open access: yesAdvanced Science, EarlyView.
A biomimetic doppelgänger nanosystem neutralizes extracellular inflammatory cytokines and silences intracellular pyroptosis, reprogramming pathogenic macrophages to attenuate both joint and spine degeneration. ABSTRACT Osteoarthritis (OA) and intervertebral disc degeneration (IVDD) are debilitating musculoskeletal disorders driven by shared ...
Fudong Li   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy