Results 1 to 10 of about 2,558 (115)
Interpreting the biological effects of protons as a function of physical quantity: linear energy transfer or microdosimetric lineal energy spectrum? [PDF]
The choice of appropriate physical quantities to characterize the biological effects of ionizing radiation has evolved over time coupled with advances in scientific understanding.
Fada Guan +10 more
doaj +3 more sources
Lineal Energy of Proton in Silicon by a Microdosimetry Simulation
Single event upset, or Single Event Effect (SEE) is increasingly important as semiconductor devices are entering into nano-meter scale. The Linear Energy Transfer (LET) concept is commonly used to estimate the rate of SEE.
Yueh Chiang +4 more
doaj +3 more sources
Proton boron capture therapy: microdosimetry and treatment planning study with boron [PDF]
BackgroundProton-boron capture therapy (PBCT) has been proposed as a method to enhance the biological effectiveness of proton therapy through the p + 11B → 3α nuclear reaction.
Seung Hoon Yoo +17 more
doaj +2 more sources
Analytic and Monte Carlo Calculations of Dose-Mean Lineal Energy for 1 MeV–1 GeV Protons With Application to Radiation Protection Quality Factor [PDF]
Petteri Nieminen
exaly +2 more sources
The spatial distribution of energy deposition events is an essential aspect in the determination of the radiobiological effects of ionizing radiation at the cellular level.
Anna Baratto-Roldán +6 more
doaj +1 more source
Miniaturized tissue equivalent proportional counters (mini-TEPCs) are proper for radiation dosimetry in medical application because the small size of the dosimeter could prevent pile-up effect under the high intensity of therapeutic beam.
Mingi Eom, Sukwon Youn, Sung-Joon Ye
doaj +1 more source
In microdosimetry, lineal energies y are calculated from energy depositions ϵ inside the microdosimeter divided by the mean chord length, whose value is based on geometrical assumptions on both the detector and the radiation field.
M. Missiaggia +22 more
doaj +1 more source
Microdosimetry Study of Proton Quality Factor Using Analytic Model Calculations
The quality factor (Q) is formally linked to the stochastic (e.g., carcinogenic) risk of diverse ionizing radiations at low doses and/or low dose rates.
Alexis Papadopoulos +5 more
doaj +1 more source
First theoretical determination of relative biological effectiveness of very high energy electrons
Very high energy electrons (VHEEs, E > 70 MeV) present promising clinical advantages over conventional beams due to their increased range, improved penumbra and relative insensitivity to tissue heterogeneities.
Rachel Delorme +4 more
doaj +1 more source
Energy-Loss Straggling and Delta-Ray Escape in Solid-State Microdosimeters Used in Ion-Beam Therapy
Microdosimetry is increasingly adopted in the characterization of proton and carbon ion beams used in cancer therapy. Spectra and mean values of lineal energy calculated in frequency and dose are seen by many as the tools which, by complementing ...
Giulio Magrin +4 more
doaj +1 more source

