Results 11 to 20 of about 6,005,333 (282)
A library of lineal energy spectra for protons.
DeCunha, Joseph Michael +2 more
openaire +2 more sources
Lineal Energy Spectra of Protons Spanning the Full Range of Clinically Relevant Energies
Lineal energy spectra calculated using the new Geant4-DNA physics models spanning energies 0 to 300 MeV.
DeCunha, Joseph Michael +5 more
openaire +2 more sources
Evaluation of a microdosimeter designed for measurement of neutron lineal energy distribution and determination of its quality factor [PDF]
Energy response of common neutron dosimeters has a significant deviation. Our goal is to construct an ambient neutron dosimeter as an array of microdosimeters whose response has less dependency on neutron energy.
Amir Moslehi +2 more
doaj +1 more source
A library of proton lineal energy spectra spanning the full range of clinically relevant energies. [PDF]
Abstract Purpose In locations where the proton energy spectrum is broad, lineal energy spectrum‐based proton biological effects models may be more accurate than dose‐averaged linear energy transfer (LET d ) based models. However,
DeCunha JM +5 more
europepmc +3 more sources
Abstract Objectives. Microdosimetry is proving to be a reliable and powerful tool to be applied in different fields such as radiobiology, radiation protection and hadron therapy. However, accepted standard protocols and codes of practice are still missing.
Gabriele Parisi +2 more
openaire +3 more sources
Lineal energy calibration of a mini-TEPC via the proton-edge technique
Abstract Purpose The possibility to calibrate microdosimetric spectra using the proton- and electron-edge was proposed many years ago. It consists of two steps: first identifying the edge and a marker point on it and then ascribing the correct lineal energy value to the position of the edge in the event size spectrum.
BIANCHI, Anna +7 more
openaire +3 more sources
Microdosimetry of diagnostic X-rays: applications of the variance-covariance method. [PDF]
Microdosimetric measurements in beams of diagnostic X rays (between 30 and 125 kV) have been performed. In these pulsed radiation fields, microdosimetric measurements are possible only by application of the variance-covariance technique.
Kellerer, Albrecht M. +3 more
core +1 more source
Bridging Microdosimetry and Macrodosimetry: A Comparative Review of Computational Approaches [PDF]
Microdosimetry does not simply refer to dosimetry with small targets, but rather to dosimetry that accounts for the stochastic nature of energy deposition.
Tatsuhiko Sato
doaj +1 more source
Development and validation of proton track-structure model applicable to arbitrary materials
A novel transport algorithm performing proton track-structure calculations in arbitrary materials was developed. Unlike conventional algorithms, which are based on the dielectric function of the target material, our algorithm uses a total stopping power ...
Tatsuhiko Ogawa +3 more
doaj +1 more source
Solar energy can be captured by Photovoltaics (PV) and converted into electrical power. This electrical power can then be connected to grids by power electronic converters, which can also operate the PV panels at around their maximum power point (MPP ...
Rodrigo Aliaga +5 more
doaj +1 more source

