Results 51 to 60 of about 11,477,062 (289)
This study presents the overall cooling effectiveness of a nozzle guide vane with impingement-effusion in the conditions of the high temperature and high pressure at the mass flow ratios from KG = 0.09 to KG = 0.14. The temperature ratios change from KT =
Chuhan Qiao +5 more
doaj +1 more source
ABSTRACT Background Patients with chronic kidney disease undergoing hemodialysis commonly experience reduced physical function, fatigue, poor sleep quality, and impaired health‐related quality of life. Intradialytic exercise has been proposed as a non‐pharmacological strategy to improve these outcomes.
Klebson da Silva Almeida +6 more
wiley +1 more source
ABSTRACT Background Chronic micro‐inflammation in patients with end‐stage renal disease (ESRD) is a significant driver of cardiovascular complications and diminished quality of life. While standard hemodialysis (SHD) effectively manages small‐molecule clearance, its ability to remove medium‐to‐large uremic toxins—the primary catalysts of systemic ...
Hongwei Zuo +5 more
wiley +1 more source
Singularities in mass-loaded MHD flow: The cometary bow shock [PDF]
We present a one-dimensional model of the mass-loading of the solar wind by cometary ions which predicts a singularity in the mass-loaded flow at M = 2. Further, a subshock occurs when the flow speed reaches M almost-equal-to 1.15.
A. J. Coates +5 more
core +1 more source
The mass flow rate and Rayleigh number has been investigated experimentally on the passive solar using Trombe wall consist of (industrial wax) used as phase change material (PCM).
Ehsan F. Abbas, Shayma A. Azat
doaj
دراسة تجريبية لمبادل حراري صفائحي كمبرد هواء
As cooling air using water injection was limited by a range of humidity ratio so indirect humidification for air consider, this research take the study of heat transfer through a perpendicular plate heat exchanger to discover the influence optimum ...
احمد أديب عبد الواحد
doaj +1 more source
Extended Mobile Bypass To Measure The Mass Flow Rate
The KONTAS-cp facility consists of a bypass with electric heating, temperature difference measurement and a Coriolis mass flow sensors to measure the specific thermal heat capacity (Cp) of heat transfer fluid (HTF). During the SFERA-II project, the measurement accuracy of the Cp-measurement is enhanced and an additional Coriolis mass flow sensor is ...
Hilgert, C., Röger, M., Aull, S.
openaire +3 more sources
ABSTRACT Introduction Hyperlipidemia is a major risk factor for atherosclerotic cardiovascular disease (ASCVD). Although statins are the cornerstone of lipid‐lowering therapy, their use may be limited in some patients by adverse effects. This study evaluated the possible impact of non‐drug treatment using double‐filtration plasmapheresis (DFPP) on CD14+
Yun Cheng +3 more
wiley +1 more source
Carbon Dioxide Absorption in Packed Column in Non-Newtonian Fluid
Absorption of carbon dioxide into carbonate solution (Na2CO3) with PAM (non-Newtonian fluid) has been performed in a countercurrent packed column (0.075m i.d. ×1.25 m height) packed with glass Raschig rings (1×1cm) to a depth of 1m.
Farah T. Jasim +2 more
doaj +1 more source
The human gut microbiome across the life course
Despite significant individual variation and continuous change throughout life, the human gut microbiome follows some life stage‐specific trends. This article provides a brief overview of how gut microbiome composition shifts across different phases of life. Created in BioRender. Özkurt, E. (2026) https://BioRender.com/8q4nrnc.
Alise J. Ponsero +4 more
wiley +1 more source

