Atomic force microscopy and Langmuir–Blodgett monolayer technique to assess contact lens deposits and human meibum extracts [PDF]
Purpose: The purpose of this exploratory study was to investigate the differences in meibomian gland secretions, contact lens (CL) lipid extracts, and CL surface topography between participants with and without meibomian gland dysfunction (MGD). Methods:
Sarah Hagedorn +5 more
doaj +2 more sources
Meibomian Gland Shortening Is Associated With Altered Meibum Composition [PDF]
The purpose of this study was to investigate differences in the composition of meibum extracted from human meibomian glands displaying different morphological characteristics.Adult participants with evidence of meibomian gland shortening were enrolled. Glands were observed using infrared meibography, and meibum was collected from one short and one long
Iqbal, F +4 more
openaire +4 more sources
Sebum/Meibum Surface Film Interactions and Phase Transitional Differences
Sebum may contribute to the composition of the tear film lipid layer naturally or as a contaminant artifact from collection. The aims of this study were to determine: if sebum changes the rheology of meibum surface films; if the resonance near 5.2 ppm in the 1H-NMR spectra of sebum is due to squalene (SQ); and if sebum or SQ, a major component of sebum,
Mudgil, Poonam (R10383) +3 more
openaire +4 more sources
Characteristics of Patients with Refractory Meibomian Gland Dysfunction Unresponsive to Intense Pulsed Light Treatment Using a Vascular Filter [PDF]
Objectives: To investigate the clinical characteristics of patients with meibomian gland dysfunction (MGD) who are refractory to additional intense pulsed light (IPL) treatment.
Yoo Young Jeon +11 more
doaj +2 more sources
Diurnal Variation of Tear and Meibum Lipids in Healthy Subjects. [PDF]
Abstract Purpose To determine whether the lipid composition of tears and meibum demonstrates diurnal variation in healthy individuals, with emphasis on the relative distribution of lipid classes.
Kumar M +5 more
europepmc +2 more sources
Alterations in the composition of meibomian gland secretions in patients with meibomian gland dysfunction based on Raman spectroscopy [PDF]
PurposeTo investigate biochemical alterations in meibum from patients with obstructive meibomian gland dysfunction (MGD) using Raman spectroscopy, with a focus on lipid saturation, molecular conformation, and lipid–protein composition.MethodsMeibum ...
Shangkun Ou +19 more
doaj +2 more sources
Human tear film and meibum. Very long chain wax esters and (O-acyl)-omega-hydroxy fatty acids of meibum [PDF]
Human meibum was targetly analyzed for the presence of intact wax esters (WEs) and related compounds by means of reverse-phase HPLC in combination with ion trap mass spectrometry.
Igor A. Butovich +2 more
doaj +3 more sources
Impact of smoking exposure on meibomian gland morphology and tear film stability: a cross-sectional study [PDF]
PurposeTo investigate the effects of smoking on the structure and function of the meibomian glands.MethodsA total of 104 chronic smokers (with a smoking history of more than 5 years) and 44 healthy non-smokers were included.
Ting Chen +3 more
doaj +2 more sources
Abnormal meibum is associated with SREBF1 mutation and IFAP Syndrome-2. [PDF]
Abstract The X-linked Ichthyosis Follicularis, Alopecia, and Photophobia syndrome type-2 (IFAP-2), is a condition that has been linked to a c.1579C>T mutation in the SREBF1 gene. However, the molecular implications of the mutation in Meibomian glands (MG) remain unknown.
Butovich IA +4 more
europepmc +4 more sources
The Meibomian Gland Composite Score (MGCS): A Novel Grading System Integrating Existing Scales for Meibomian Gland Dysfunction [PDF]
Kaleb S Abbott,1 Anna A Tichenor,2 Stephanie Martich,1 Andrew D Pucker31Department of Ophthalmology, Sue-Anschutz Rodgers Eye Center, University of Colorado School of Medicine, Aurora, CO, USA; 2School of Optometry, Indiana University, Bloomington, IN ...
Abbott KS +3 more
doaj +1 more source

