Results 261 to 270 of about 4,019,710 (295)
Some of the next articles are maybe not open access.

Determination of iron(II) with chemically-modified carbon-paste electrodes

Talanta, 1991
The utility of carbon-paste electrodes modified with 2,2'-bipyridyl and Nafion for the differential pulse voltammetric determination of iron(II) in aqueous medium is demonstrated. The method is based on formation of the 2,2'-bipyridyl complex of iron(II) and its accumulation by the Nafion. The differential pulse voltammetric response of the accumulated
Z, Gao, P, Li, Z, Zhao
openaire   +2 more sources

Determination of gold using clay modified carbon paste electrode

Fresenius' Journal of Analytical Chemistry, 2000
Sorption of gold(III) chlorocomplexes was studied by means of a carbon paste electrode modified with montmorillonite. Anionic exchange behavior was found in chloride media with low ionic strength. Anionic sorption of [AuCl4]- can be used as a preconcentration step to the determination of Au(III).
Z, Navrátilová, P, Kula
openaire   +2 more sources

Determination of Pb(II) with a Dithizone-Modified Carbon Paste Electrode

Journal of Environmental Science and Health, Part A, 2006
A dithizone (DTZ) modified carbon paste electrode was developed for the sensitive and selective determination of Pb(II) using differential pulse anodic stripping voltammetry as well in batch as in FIA system. The analysis procedure is based on an open circuit accumulation step in a stirred sample solution.
Ma Dolores, Vázquez   +2 more
openaire   +2 more sources

Voltammetric determination of linuron at a carbon-paste electrode modified with sepiolite

Talanta, 1990
The determination of linuron by differential pulse voltammetry with a carbon-paste electrode modified with 20% w/w sepiolite has been studied. The linuron is preconcentrated under open-circuit conditions at pH 2.0. With 0.01M potassium nitrate at pH 1.7 in the measurement cell, a sweep rate of 30 mV/sec and a pulse amplitude of 100 mV, an oxidation ...
P, Hernandez   +3 more
openaire   +2 more sources

Voltammetric study of glibenclamide at carbon paste and Sephadex-modified carbon paste electrodes

Analytical and Bioanalytical Chemistry, 2004
The oxidative behaviour of the antidiabetic agent glibenclamide on a bare carbon paste electrode (CPE) and a Sephadex-modified carbon paste electrode (SMCPE) was explored by cyclic and differential pulse voltammetry (DPV). The analysis procedure consisted of an open circuit accumulation step in stirred sample solution of Britton-Robinson buffer (0.04 ...
openaire   +2 more sources

Electrochemical behaviour of clenbuterol at nation-modified carbon-paste electrodes

Journal of Pharmaceutical and Biomedical Analysis, 1995
A detailed study of the electrochemistry of clenbuterol at bare carbon-paste electrodes (CPEs) has been carried out. Results showed that clenbuterol undergoes an ECE process. This compound is irreversibly oxidised at high potentials, resulting in the formation of a product which demonstrates quasi-reversible electrochemical behaviour at less positive ...
S, Moane   +4 more
openaire   +2 more sources

Amperometric biosensors for glucose based on carbon paste modified electrodes

Talanta, 1991
The modification of carbon-paste electrodes by incorporation of the enzyme glucose oxidase (GOD) is described. The resulting probes can be operated as amperometric glucose sensors in the presence or absence of a mediator (1,1'-dimethylferrocene) mixed into the paste.
Kauffmann, Jean-Michel   +2 more
openaire   +3 more sources

ALCOHOL DETERMINATION BY MODIFIED CARBON PASTE ELECTRODES

2023
The basis of this alcohol sensor is the oxidation of ethanol by NAD* with alcohol dehydrogenase as the catalyzing enzyme. The NADH formed is detected electrochemically at 700 mV versus a Ag/AgCl-electrode. The electrode used is a carbon paste electrode with the enzyme and the cofactor mixed into the paste. The sensor can be used up to concentrations of
Bilitewski, Ursula, Schmid, Rolf D.
openaire   +1 more source

The electrocatalytic examination of cephalosporins at carbon paste electrode modified with CoSalophen

Talanta, 2007
The electrocatalytic oxidation of cephalexin and cefazolin has been studied at a carbon paste electrode modified with cobalt salophen (CoSal) by cyclic voltammetry. The selectivity of the carbon paste modified with CoSal in detecting cephalexin and cefazolin was examined. To suggest the electrocatalytic mechanism for electro-oxidation of cefazolin, the
E S, Jamasbi   +4 more
openaire   +2 more sources

Voltammetric characterization of activated carbons in modified carbon paste electrodes

Electroanalysis, 1993
AbstractCarbon paste electrodes (CPEs), modified by the addition of small amounts of finely powdered activated carbon (AC) were studied using cyclic (CV) and square wave voltammetry (SWV). Cyclic voltammograms revealed the expected increase in surface area associated with the presence of the activated carbon but did not reveal any specific redox peaks.
Jeffrey D. Kaplan   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy