Results 41 to 50 of about 12,013 (216)

Influence of the VSC-HVDC System Structure on the Overvoltage of Single-Pole Grounding Fault

open access: yesZhongguo dianli, 2021
Flexible operation mode is one of the VSC-HVDC system’s advantages, and the power system may continue to operate in the future with different grid structures under maintenance and other working conditions.
Jialing WU, Tiebing LU
doaj   +1 more source

Infinite Functional Versatility, Formidable Limits: Evaluating Gallium‐Based Liquid Metals in Rechargeable Batteries

open access: yesCarbon Energy, EarlyView.
Beyond the hype surrounding the self‐healing properties of gallium‐based liquid metals (Ga‐LMs), this perspective critically examines their functional roles in metal‐ion batteries, highlighting both their underlying merits and the often‐overlooked challenges, including non‐representative design and testing configurations, performance overestimations ...
Turly P. P. Sumanasekara   +7 more
wiley   +1 more source

Analysis on switching overvoltage and suppression method of cable joint in 500 kV cable line

open access: yesEnergy Reports, 2021
The breakdown accident of cable joint occurs frequently when the sheath overvoltage cable line is closed, but the cable joint is ignored or simply treated in the previous overvoltage simulation of cable system.
Hongtao Ren, Ying Zhang
doaj   +1 more source

Laser‐Textured Field‐Engineered Interface for Robust Dry‐Processed Cathodes in Lithium‐Ion Batteries

open access: yesENERGY &ENVIRONMENTAL MATERIALS, EarlyView.
Laser‐patterned dry electrodes applied to current collectors could serve as a promising alternative to the limitations of conventional dry electrodes. Laser technology provides a fast and simple method to enhance the surface roughness of current collectors, improving the adhesion at the electrode–current collector interface.
Chaerin Jung   +8 more
wiley   +1 more source

A Comprehensive Review of Fault‐Current Limiter Technologies for Smart and Resilient Power Systems

open access: yesEnergy Science &Engineering, EarlyView.
This review compares superconducting, solid‐state, and hybrid fault‐current limiters (FCLs) for modern alternating current, direct current, and hybrid grids. It shows that optimal FCL selection depends on fault characteristics, network configuration, voltage level, protection coordination, and resilience requirements rather than on a universally ...
Abdelrahman Farghly   +5 more
wiley   +1 more source

A Preventive Static Security Control Strategy for Distribution Networks Based on Phase Shifting Transformer Loop‐Closing Devices

open access: yesIEEJ Transactions on Electrical and Electronic Engineering, EarlyView.
As the share of renewable energy in the energy mix continues to increase, the penetration of distributed renewable generation in distribution networks is also rising steadily. Loop‐closing operation provides an effective means to enhance renewable energy accommodation across different grid partitions.
Ningyu Zhang   +6 more
wiley   +1 more source

SiC MOSFET turn-off overvoltage measurement [PDF]

open access: yes
International audienceSelecting the appropriate measurement system is crucial in power electronics. This is especially important during MOSFET's turn-off process, where it is essential to measure the voltage rise and accurately capture the peak ...
Galdeano, Mikel   +3 more
core   +2 more sources

Probe on Problems of Combined Overvoltage Protector in Lightning Protectio

open access: yesGong-kuang zidonghua, 2012
The paper analyzed accidents in application of combined overvoltage protector in a substation in Yangquan mining area of Shanxi province and a pumped storage power station in Hubei province. It introduced principle and working characteristics of combined
YI Xiao-fei   +3 more
doaj  

Evaluation Methodology, Numerical Verification and Retrofilling Procedure for Power Transformers to Ensure K‐Class Flame Retardancy and Environmentally Friendly

open access: yesHigh Voltage, EarlyView.
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang   +5 more
wiley   +1 more source

Avoiding PV-Induced Overvoltage through Grid-Connected Batteries Using Model Predictive Control

open access: yesEnvironmental and Climate Technologies, 2023
The problem of temporary overvoltage when integrating large renewable power plants into the existing grid is considered. A grid-connected battery energy storage system with an advanced predictive control algorithm is proposed to reduce the overvoltage in
Kirchsteiger Harald, Landl Sarah
doaj   +1 more source

Home - About - Disclaimer - Privacy