Results 61 to 70 of about 2,972 (191)
Study of Power Frequency Overvoltage Suppression on UHV Transmission Line
It mainly studied the improvement measures of overvoltage level for UHV transmission line from Jindongnan to Jingmen. It analyzed single-phase grounding load shedding overvoltage and fault-free load shedding overvoltage in the case of the single ...
HAN Mengmeng +3 more
doaj
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley +1 more source
When the electric locomotive pantograph is dropping, the interruption of pantograph catenary contact causes electromagnetic oscillation and arcing. The frequent arc burning that occurs due to charge accumulation results in the amplitude of overvoltage ...
Dazuo Jiang +5 more
doaj +1 more source
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang +4 more
wiley +1 more source
Research on overvoltage and fault of a UHV AC/DC hybrid system
In view of the overvoltage problem of an ultra-high-voltage DC (UHVDC) AC/DC hybrid system, this study analyses the overvoltage condition under various fault types and gives the identification criterion of the overvoltage form. Firstly, the model of the
Yali Wang +3 more
doaj +1 more source
Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device
ABSTRACT Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc ...
Yeqiang Deng +4 more
wiley +1 more source
Novel method for restraining 35 kV shunt reactor switching overvoltage – phase controlled breaker
Phenomena such as current chopping, arc reignition and equivalent current chopping might appear when cutting off shunt reactor. Overvoltage caused by switching will lead to interphase fault in related equipment and inter-turn insulation damage in the ...
Yiming Zheng +5 more
doaj +1 more source
Abstract Continuous, high‐frequency monitoring is essential to capture rapid phenological transitions and dynamic crop responses to the environment. However, most phenotyping platforms lack the temporal resolution and automation required for consistent, season‐long trait assessment.
Worasit Sangjan +5 more
wiley +1 more source
Overvoltage caused by faults or switching is one of the decisive factors affecting the insulation level of equipment in UHVDC transmission systems.
Xiaoguang Zhu +6 more
doaj +1 more source
Toward Safer and Sustainable Lithium Metal Batteries: Fluorine‐Free Solid Polymer Electrolytes
An analysis to assess the impact of fluorine in polymer electrolyte‐based lithium metal batteries has been conducted. It has been demonstrated that fluorine‐free LiTIM salt delivers a electrochemical performance similar to that of its fluorinated analogue salts, given the complete lithium dissociation in coordination with PEO and the restricted anion ...
David Fraile‐Insagurbe +10 more
wiley +1 more source

