Results 71 to 80 of about 32,313 (287)

Anomalous Sodium Insertion in Highly Oriented Graphite: Thermodynamics, Kinetics and Evidence for Two‐Sided Intercalation

open access: yesAngewandte Chemie, Volume 138, Issue 19, 4 May 2026.
Sketch for chemical Na bilayer (a) aggregation to higher aggregates (b), resulting in loss of space charge zones. The electrons compensating for the Na+ are partly in the space charge layers and partly in‐between the Na‐layers. ABSTRACT The difficult intercalation of sodium (Na) into graphite is studied by systematic and long‐time investigations (of up
Chuanhai Gan   +7 more
wiley   +2 more sources

Evaluation Methodology, Numerical Verification and Retrofilling Procedure for Power Transformers to Ensure K‐Class Flame Retardancy and Environmentally Friendly

open access: yesHigh Voltage, EarlyView.
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang   +5 more
wiley   +1 more source

Mechanism Analysis and Simulation Study of Closing Overvoltage Fault in EMU Circuit Breaker

open access: yesChengshi guidao jiaotong yanjiu
Objective The overvoltage caused by circuit breaker closing will aggravate the insulation aging of high voltage equipment when EMU (electric multiple units)passes neutral section.
ZHANG Mingrui   +2 more
doaj   +1 more source

Correlated Transient Response of Buried Cables and Lightning Channel Radiation of Return Strokes of Five Rocket‐Triggered Lightning Strikes

open access: yesHigh Voltage, EarlyView.
ABSTRACT Data from five rocket‐triggered lightning flashes are adopted to analyse the correlated transient response of buried cables and lightning channel radiations. These five flashes have the same termination point that is right above the buried cables and involve a total of 32 return strokes.
Mi Zhou   +9 more
wiley   +1 more source

Power operation region modeling and transient overvoltage suppression strategy of hybrid cascaded HVDC

open access: yesInternational Journal of Electrical Power & Energy Systems
The hybrid cascaded HVDC system(HC-HVDC) in sending end system is composed of an Line Commutated Converter(LCC) connected in series with a parallel group of Modular Multilevel Converters (MMC).
Jiangshan Liu   +5 more
doaj   +1 more source

A Modelling Tool for Distribution Networks to Demonstrate Smart Grid Solutions [PDF]

open access: yes, 2014
The increased deployment of low carbon technologies in power distribution networks, particularly at the distribution level, is expected to cause significant problems to network operation unless existing networks are appropriately adapted and actively ...
Bentley, Edward   +2 more
core   +1 more source

Arc Resistance Enhancement of Converter Transformer Tank Through Structural Improvements: Simulation and Experimental Validation

open access: yesHigh Voltage, EarlyView.
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang   +5 more
wiley   +1 more source

Study of Switching Overvoltage Protection Measures for Capacitor Compensation Device

open access: yesKongzhi Yu Xinxi Jishu, 2014
The harm of using damping and limiting measures to eliminate switching overvoltage of FC device was analyzed in theory and simulation. It presents that input overvoltage protection mainly depends on the insulation capability of the device and the effect ...
JIANG Jiajiu   +4 more
doaj  

Study on Impurity Particle Detection in Transformer Oil Based on Microflow Imaging Method

open access: yesHigh Voltage, EarlyView.
ABSTRACT The concentration of particles in transformer oil has a significant influence on its electrical performance, making oil cleanliness a critical parameter in the operation and maintenance of power transformers. However, the light obstruction (LO) method recommended by current standards has inherent limitations, including low sensitivity to ...
Chen Chen   +6 more
wiley   +1 more source

Determination of protection system requirements for DC UAV electrical power networks for enhanced capability and survivability [PDF]

open access: yes, 2011
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme   +3 more
core   +1 more source