Results 51 to 60 of about 8,357 (239)
Laser‐Textured Field‐Engineered Interface for Robust Dry‐Processed Cathodes in Lithium‐Ion Batteries
Laser‐patterned dry electrodes applied to current collectors could serve as a promising alternative to the limitations of conventional dry electrodes. Laser technology provides a fast and simple method to enhance the surface roughness of current collectors, improving the adhesion at the electrode–current collector interface.
Chaerin Jung +8 more
wiley +1 more source
Feature statistics and analysis of transient overvoltage waveform measured from 220 kV substation
The electromagnetic transient overvoltage in the substation is an important factor that affects the life of insulation equipment. For evaluate the economy and reliability of the insulation design of substation equipment, it is necessary to study and ...
Chenmeng Zhang +7 more
doaj +1 more source
General framework of ensemble learning technique for transformer fault diagnostics compared with traditional dissolved gas analysis methods. ABSTRACT This paper implemented a comprehensive variety of modern machine‐learning techniques, which were demonstrated to be effective in handling complex tabular data, generating accurate predictions, and ...
Osama E. Gouda +3 more
wiley +1 more source
Smart charging with hourly pricing optimizes electric vehicle (EV) charging in developing countries, reducing EV owner costs by 30% and easing grid congestion. Using an agent‐based energy management system, the study shows dynamic pricing effectively shifts charging to off‐peak hours, enhancing grid stability and supporting sustainable EV adoption in ...
Maha Iftikhar +8 more
wiley +1 more source
A New Method to Overvoltage Restrain of ElectricLocomotive Passing the Neutral Section
Overvoltage problem caused by electric locomotive passing the neutral section, always result in traction substation trip or the arc eroding the contact line.
LI Zong-lei +3 more
doaj
Addressing Overvoltage Protection for High Voltage Loads
In most of the electrical systems mainly the damage is caused by overvoltage and excess current. This paper addresses the methods and issues related with the overvoltage protection for high voltage loads.
, Shahera S. Patel
core +1 more source
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang +5 more
wiley +1 more source
Mechanism Analysis and Simulation Study of Closing Overvoltage Fault in EMU Circuit Breaker
Objective The overvoltage caused by circuit breaker closing will aggravate the insulation aging of high voltage equipment when EMU (electric multiple units)passes neutral section.
ZHANG Mingrui +2 more
doaj +1 more source
ABSTRACT Data from five rocket‐triggered lightning flashes are adopted to analyse the correlated transient response of buried cables and lightning channel radiations. These five flashes have the same termination point that is right above the buried cables and involve a total of 32 return strokes.
Mi Zhou +9 more
wiley +1 more source
The hybrid cascaded HVDC system(HC-HVDC) in sending end system is composed of an Line Commutated Converter(LCC) connected in series with a parallel group of Modular Multilevel Converters (MMC).
Jiangshan Liu +5 more
doaj +1 more source

