Results 1 to 10 of about 3,351 (189)
Analysis of suppression switching overvoltage for CRAFT power supply
In order to solve the problem of switching overvoltage for CRAFT, an optimal design is put forward to suppress overvoltage, which aims to enable the converter thyristor work normal.
Yalong Yang +4 more
doaj +2 more sources
Mechanism and suppression of breaking overvoltage of DC circuit breakers
The occurrence of breaking overvoltage in a DC circuit breaker (DCCB) poses a potential threat to the safe operation of a DC grid. Based on the structure of the ±10 kV three‐terminal DC distribution network, this paper sets up the medium‐voltage DCCB and
Lu Qu +7 more
doaj +2 more sources
In this study, a LCC-VSC hybrid HVDC transmission system was taken as an example. The valve and neutral overvoltage of the hybrid HVDC system were simulated and then calculated at the VSC converter station by installing a blocking diode and a DC circuit ...
Wang Dongju, Zhou Hao
doaj +1 more source
During the switching operation of the non-load power transmission lines, the undisired switching overvoltage issue is inevitable, causing grid voltage oscillations, waveform distortion and other phenomena at the end of the non-load power transmission ...
Bo Yang +4 more
doaj +1 more source
The high amplitude and steep overvoltage generated by the breaking of the vacuum circuit breaker in the wind farm damages the inter-turn insulation of the transformer.
Ziheng Pu +4 more
doaj +1 more source
In grounding fault of DC system, overvoltage will appear on equipment nodes in converter station. Due to different operation mode and equipment type, it is very different from overvoltage in AC system.
Zongyang Zhang +5 more
doaj +1 more source
Aiming at the transient overvoltage problem of high proportion new energy multi direct current (DC) transmission system caused by DC blocking fault, the interaction mechanism between multiple DC lines is analyzed firstly and the multi-outfeed voltage ...
ZHANG Qirui +5 more
doaj +1 more source
With the development of the photovoltaic industry; there will be an increasing demand for efficient, high-power density, and low-cost grid interface converters.
Jian Yu +4 more
doaj +1 more source
This paper presents a design and performance evaluation of three different overvoltage suppression circuits employed in a solid-state circuit breaker for medium- to high-power and low- to medium-voltage DC grids.
Andreas Giannakis, Dimosthenis Peftitsis
doaj +1 more source
Novel method for restraining 35 kV shunt reactor switching overvoltage – phase controlled breaker
Phenomena such as current chopping, arc reignition and equivalent current chopping might appear when cutting off shunt reactor. Overvoltage caused by switching will lead to interphase fault in related equipment and inter-turn insulation damage in the ...
Yiming Zheng +5 more
doaj +1 more source