Impact of using a perioperative artificial endocrine pancreas in pancreatic resection
Aim Pancreatectomy causes both hyperglycemia, secondary to surgical stress, and pancreatic diabetes, which leads to difficult‐to‐control postoperative blood glucose levels.
Toshiaki Yoshimoto +8 more
doaj +1 more source
Current Status of Continuous Glucose Monitoring Use in South Korean Type 1 Diabetes Mellitus Population–Pronounced Age-Related Disparities: Nationwide Cohort Study [PDF]
Background This study aims to identify the status of continuous glucose monitoring (CGM) use among individuals with type 1 diabetes mellitus (T1DM) in South Korea and to investigate whether age-related disparities exist.
Ji Yoon Kim, Seohyun Kim, Jae Hyeon Kim
doaj +1 more source
Modelling glucose dynamics during moderate exercise in individuals with type 1 diabetes.
The artificial pancreas is a closed-loop insulin delivery system that automatically regulates glucose levels in individuals with type 1 diabetes. In-silico testing using simulation environments accelerates the development of better artificial pancreas ...
Haneen Alkhateeb +3 more
doaj +1 more source
Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis. [PDF]
OBJECTIVE: To evaluate the efficacy and safety of artificial pancreas treatment in non-pregnant outpatients with type 1 diabetes. DESIGN: Systematic review and meta-analysis of randomised controlled trials. DATA SOURCES: Medline, Embase, Cochrane Library,
Athanasiadou, Eleni +8 more
core +1 more source
Blood Glucose Regulation Using Labview [PDF]
Diabetes mellitus (DM), commonly referred to as diabetes, is a group of metabolic diseases in which there are high blood sugar levels over a prolonged period. If not regulate the glucose level then it will cause the serious damage to heart, kidneys, eyes,
Balaji, V. (V) +2 more
core +1 more source
Free-living use of artificial pancreas for children with type 1 diabetes: systematic review
BACKGRAUND: A closed-loop glucose control system or ‘artificial pancreas’ consists of three components – a Continuous Glucose Monitor (CGM), infusion pumps to deliver hormone(s) and a sophisticated dosing algorithm to control hormone ...
Klemen Dovc +8 more
doaj +1 more source
Continuous glucose monitoring sensors: Past, present and future algorithmic challenges [PDF]
Continuous glucose monitoring (CGM) sensors are portable devices that allow measuring and visualizing the glucose concentration in real time almost continuously for several days and are provided with hypo/hyperglycemic alerts and glucose trend ...
Facchinetti, Andrea
core +2 more sources
Development platform for artificial pancreas algorithms.
Background and aimsAssessing algorithms of artificial pancreas systems is critical in developing automated and fault-tolerant solutions that work outside clinical settings.
Mohamed Raef Smaoui +2 more
doaj +1 more source
TEAD and YAP regulate the enhancer network of human embryonic pancreatic progenitors. [PDF]
The genomic regulatory programmes that underlie human organogenesis are poorly understood. Pancreas development, in particular, has pivotal implications for pancreatic regeneration, cancer and diabetes.
A Kapoor +67 more
core +2 more sources
An implantable artificial pancreas [PDF]
The artificial implantable pancreas is seen as the optimal means of therapy in patients with severe diabetes mellitus. The implantable pancreas consists of three modules; (i) the dosing unit, (ii) the control circuit and (iii) a glucose sensor for the realisation of a feedback system.
Schubert, Wolfgang +4 more
openaire +3 more sources