Results 81 to 90 of about 92,448 (240)
Tumour heterogeneity and clonal evolution of metastatic salivary gland cancer were evaluated in two patients with adenoid carcinoma and one patient with myoepithelial carcinoma. Radiology‐guided autopsy enabled multi‐region sampling (total samples n = 149), followed by whole‐genome sequencing and phylogenetic reconstruction (17 tumour samples, 4–7 per ...
Gerben Lassche +10 more
wiley +1 more source
Pre-Analytical Laboratory Errors and Their Impact on Diagnostic Accuracy
Pre-analytical laboratory errors refer to the mistakes that occur before the actual analysis of biological specimens, significantly impacting the overall accuracy of diagnostic testing. These errors can arise from various sources, including patient misidentification, improper collection techniques, inadequate specimen handling, and delays in ...
null Shuhrah Helal Hassan Alharthi +10 more
openaire +1 more source
RoboMic is an automated confocal microscopy pipeline for high‐throughput functional imaging in living cells. Demonstrated with fluorescence recovery after photobleaching (FRAP), it integrates AI‐driven nuclear segmentation, ROI selection, bleaching, and analysis.
Selçuk Yavuz +6 more
wiley +1 more source
Since laboratory tests provide essential information for physicians to make medical decisions for diagnosis, treatment and monitoring of the patient’s condition, we evaluated the types and frequency of errors in our in-patient department ...
Pakasit Pratoomtone
doaj
CHARACTERISTICS OF PRE-ANALYTICAL STAGE IN IMMUNOPHENOTYPING OF PERIPHERAL BLOOD CELLS
. Application of flow cytometry (FC) techniques has considerably expanded the opportunities for evaluation of immune cells, aiming for better diagnostics of immunodeficiency disorders, autoimmune and lymphoproliferative diseases, etc.A procedure of ...
L. V. Serebrovskaya +2 more
doaj +1 more source
Unique biological samples, such as site‐specific mutant proteins, are available only in limited quantities. Here, we present a polarization‐resolved transient infrared spectroscopy setup with referencing to improve signal‐to‐noise tailored towards tracing small signals. We provide an overview of characterizing the excitation conditions for polarization‐
Clark Zahn, Karsten Heyne
wiley +1 more source
Evaluating the Completeness of Histopathology Sample Labeling [PDF]
Background and Aim: A major quality assurance target is minimizing error rates to enhance patient safety. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs.
Fariba Abbasi Kokia, Nazila Ahmadi
doaj
Does cleaning of venipuncture site with alcohol affect blood ethanol concentration?
Background: It is important to accurately determine the blood ethanol concentration (BEC) to ensure appropriate diagnosis and treatment of patients in the emergency department (ED) and protect their legal rights.
Deniz Kılıç +6 more
doaj +1 more source
YIPFα1A expression is regulated by multilayered molecular mechanisms
YIPFα1A, a five‐pass Golgi protein, is regulated at multiple layers. (1) Rare‐codon enrichment drives translation‐coupled mRNA decay. (2) A proximal 3′‐UTR element stabilizes mRNA. (3) A distal 3′‐UTR element included by alternate poly(A) site usage represses translation, which can be overridden by the proximal 3′‐UTR element.
Tokio Takaji +2 more
wiley +1 more source
The MRP4 transporter exports several drugs and signaling molecules. Here, we identified key promoter elements regulating basal MRP4 expression. Using reporter assays, we defined a conserved region with essential Sp1 and contributory Ets sites, which controlled basal MRP4 expression.
Debora Singer +7 more
wiley +1 more source

