Results 151 to 160 of about 30,007 (261)

Experimental methods in chemical engineering: Temperature‐programmed oxidation—TPO

open access: yesThe Canadian Journal of Chemical Engineering, EarlyView.
Abstract Temperature‐programmed oxidation (TPO) probes the oxidative capacity and redox properties of solid materials—catalysts, metal oxides, perovskites, and carbonaceous deposits. It identifies coke type, distribution, and reactivity. TPO instruments pass an oxidizing gas (diluted O2$$ {\mathrm{O}}_2 $$, air, or less commonly N2O$$ {\mathrm{N}}_2 ...
Gholamreza Roohollahi   +7 more
wiley   +1 more source

Low-Temperature Defect Healing in the Layered Zintl Phase Li<sub>2</sub>ZnSi. [PDF]

open access: yesInorg Chem
Feng XJ   +8 more
europepmc   +1 more source

Molten‐Salt‐Mediated Chemical Looping Oxidative Dehydrogenation of Ethane with In‐Situ Carbon Capture and Utilization

open access: yesChemSusChem, Volume 18, Issue 6, March 15, 2025.
A sustainable alternative to steam cracking, the molten‐salt‐mediated oxidative dehydrogenation (MM‐ODH) of ethane (C2H6) in Li2CO3‐Na2CO3‐K2CO3 (LNK) couples thermal cracking with melt‐mediated CO2 capture to realize commercially competitive C2H4 and CO yields. LNK composition strongly influences MM‐ODH process outcomes.
Kyle Vogt‐Lowell   +6 more
wiley   +1 more source

Plasmakristall‐4 Experiment: 10 Years of Operation in Orbit

open access: yesContributions to Plasma Physics, EarlyView.
ABSTRACT Plasmakristall‐4 (PK‐4) is a microgravity complex plasma laboratory operated for 10 years on board the International Space Station. Its main purpose is the particle‐resolved investigation of generic condensed matter phenomena using strongly coupled suspensions of microparticles immersed in low‐pressure gas‐discharge plasmas.
M. Pustylnik   +3 more
wiley   +1 more source

Micro‐QuEChERS Extraction for Broad‐Spectrum LC‐QQQ‐MS Quantification of Nitazene Analogs in Plasma: A Validated Method With Casework Application

open access: yesDrug Testing and Analysis, EarlyView.
Micro‐QuEChERS sample preparation coupled to LC‐QQQ‐MS enabled sensitive quantification of nitazene analogs in 100 μL of plasma. The validated method provided low detection limits and was successfully applied to an authentic intoxication case involving N‐pyrrolidino protonitazene, supporting clinical and forensic toxicology workflows.
Karla A. O. Souza   +7 more
wiley   +1 more source

Unveiling Spin Transition at Single-Particle Level in Levitating Spin Crossover Nanoparticles. [PDF]

open access: yesACS Nano
Pinilla-Cienfuegos E   +6 more
europepmc   +1 more source

Detection of Nitazenes in the Illicit Drug Supply Utilizing Precursor Ion Scan Methods With Paper Spray Mass Spectrometry

open access: yesDrug Testing and Analysis, EarlyView.
Nitazenes are increasingly present in the illicit drug supply, complicating harm reduction efforts. We have developed a rapid, nontargeted precursor ion scan method to detect emerging nitazenes in real‐world opioid samples. The method identified multiple nitazenes, often replacing pharmaceutical opioids or mixed with fentanyl and benzodiazepines ...
Allie Miskulin   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy